Maintenance
3000 - Cooling system
Inspecting the engine visually
Make sure that the following preconditions are met:
q Preparatory maintenance activities are fulfilled.
p. 100)
u Visually inspect the engine according to task SL0-1011.
condition — SL0-1011, p. 105)
Checking coolant level
Previous tasks
Make sure that the following preconditions are met:
q Preparatory maintenance activities are fulfilled.
p. 100)
Specific safety instructions
See general instructions above.
Consumables and equipment
Make sure that the following consumables and equipment are available:
– Required volume of fresh approved coolant
Topping up coolant level
u Refer to the generator set documentation to check the coolant level.
u Top up the cooling system with KOHLER approved engine coolant.
ants, p. 190)
5.8.2 Changing coolant — SL1-3020
Previous tasks
Make sure that the following preconditions are met:
q Preparatory maintenance activities are fulfilled.
p. 100)
Specific safety instructions
DANGER
Fire - Ignition of flammable materials and operating fluids: fuel, lubricating oil, or coolant!
Risk of death or injury by burn, scald, or asphyxiation.
u Make sure that no operating fluid comes into contact with a hot surface or an ignition
source.
u Before servicing the engine, let it cool down until surface temperature allows you to touch it
with bare hand.
u Before servicing the engine, make sure that the operating fluid pressures are relieved.
154
(→ 5.12.1 Filling volume, p. 177)
© 2023 by Kohler Co. All rights reserved.
(→ 5.4 Preparatory maintenance activities,
(→ 5.6.1 Inspecting engine overall
(→ 5.4 Preparatory maintenance activities,
(→ 5.12.4 Approved cool‐
(→ 5.4 Preparatory maintenance activities,
KD62V12A 33521061401_1_1 EN_US