When charging any G-Series Refrigerator with R-450A refrigerant care should be taken to weigh the proper
amount of liquid refrigerant into the system according to the data plate. It is important to charge with
refrigerant in a liquid state to avoid fractionating.
1.5.2.1
Pressure/ Temperature Chart for R-450A Refrigerant
Figure 4: R-450 Blend
58%
42%
Table 1 R-450 Refrigerant Composition
Pressure
10 PSIG
15 PSIG
20 PSIG
25 PSIG
30 PSIG
35 PSIG
40 PSIG
Dew
Bubble
13.2°F
12.9°F
21.7°F
20.6°F
29.2°F
28.0°F
35.8°F
34.7°F
41.8°F
40.7°F
47.4°F
46.2°F
52.5°F
51.4°F
R134A
R1234ZE