OWNER'S MANU
I. RECEIPT & SUPPORT INSTALLATION:
You should carefully inspect your Traulsen unit for damage during
delivery. If damage is detected, you should save all the crating
materials and make note on the carrier's Bill Of Lading describing
this. A freight claim should be filed immediately.
After uncrating the unit, select a level location for final place-
ment. Install the legs or casters as shown below or, in the case of
roll-in and roll-thru models, these must be sealed to the floor in
accordance with local health codes.
Some models may use R-290 (Propane) as
a refrigerant. If flammable refrigerant is present, follow
instructions as labeled on the unit. Proper care must be
taken to avoid any damage to refrigeration system includ-
ing refrigerant tubing, condenser, evaporator coils during
handling, moving, installation and cleaning as it may cause
risk of fire or explosion. If damaged, unit must be moved to
well ventilated area away from any sources of ignition.
Further service and repair must be performed by qualified
refrigeration technicians familiar with applicable safety
standards for flammable refrigerants. Technicians must use
appropriate personal protective equipment and follow ap-
plicable safety precautions to avoid risk of fire or explosion.
R & A Series/G Series Supports ("Stem" type legs)
TE/TU/TS Series Supports
Compacts Supports ("Stem" type legs & casters)
Instructions for the installation, use and care of:
R & A Series
G Series
Compact Undercounter & Prep-Table
TE Series/TU Series/TS Series
AL
* Traulsen's equipment stands are solely intended for use with cooking equipment.
All models (except undercounters) should be installed to allow at
least 12" of clear space above the unit. In all cases the louvers must
be free of any obstruction which could prevent proper air-flow.
Most units are supplied with a cord and plug, which can simply
be plugged into a dedicated appropriately sized outlet. For those
requiring hard-wiring directly to the power supply, this should be
done by only a qualified electrician.
NOTE: Some models require
provision of a bottom mounted
condensate evaporator. Follow in-
structions provided with part, along
with this for installation.
II. OPERATION:
refrigerant. Consult detailed owner's manual available at www.
traulsen.com before attempting to install or service units with
R-290 or other flammable refrigerants. All safety precautions
must be followed to avoid risk of fire or explosion. Contact
Traulsen technical assistance for additional information at
800-825-8220.
Most Traulsen equipment is plug and play, such as G Series and
most Compacts. However, once power is supplied to the unit,
some may require simple steps to get started using your Traulsen
equipment, such as the: R & A Series, TE Series, TU Series and
TS Series Cabinets.
Although fully operational the control will flash the cabinet tem-
perature alternatively with the message ELE LOS (power loss).
Press the alarm cancel button
R & A Series Control
Some models may use R-290 (Propane) as a
to cancel this message.
TE/TU/TS Series Control
Alarm Cancel Button
TR35924 P/N 375-60293-00 (REV-E-07-08-15)

Advertisement

loading

Summary of Contents for Traulsen R & A Series

  • Page 1 G Series Compact Undercounter & Prep-Table Quality Refrigeration TE Series/TU Series/TS Series * Traulsen’s equipment stands are solely intended for use with cooking equipment. OWNER’S MANU I. RECEIPT & SUPPORT INSTALLATION: All models (except undercounters) should be installed to allow at You should carefully inspect your Traulsen unit for damage during least 12”...
  • Page 2 Defrost Lockout Feature II. OPERATION: (continued) Defrost lockouts will allow you to prevent defrost cycles from oc- Hot Food Holding Cabinets curring for two hours during a designated time. Up to four can be Are shipped in the Off position. To begin use, first press the ON/ set for any 24-hour period.
  • Page 3 You can use the up or down arrow keys to the next parameter or press the alarm All Traulsen equipment should be cleaned only with warm water, cancel button to exit or leave inactive for 30 seconds. mild soap and a soft cloth. Apply with a dampened cloth and wipe in the direction of the metal grain.
  • Page 4: Troubleshooting

    Before making contact, please make sure you have model and serial number of the unit. Amp plate with information needed is located on the unit. Amp Plate Please visit our website at www.traulsen.com for additional service and parts information. From our home page click on the SERVICE & PARTS tab, and select one of the following: SERVICE FINDER...
  • Page 5 Réfrigération de qualité de préparation Gammes TE/TU/TS GUIDE D’UTILISATION * Les porte-équipement de Traulsen sont destinés à être utilisés uniquement pour le support des appareils de cuisson. I. RÉCEPTION & INSTALLATION DES SUPPORTS : Tous les modèles (sauf les modèles sous-comptoir) doivent être installés avec un dégagement d’au moins 12 po (305 mm)
  • Page 6 II. FONCTIONNEMENT: (suite) Fonction de verrouillage du dégivrage Le verrouillage du dégivrage permet d’éviter les cycles de dégivrage pendant Les armoires chauffantes deux heures au cours d’une période définie. Vous pouvez régler jusqu’à Les armoires sont livrées en position Arrêt. Pour commencer à les quatre cycles sur une période de 24 heures.
  • Page 7 . L’affichage indiquera alors l’horloge . Vous pouvez utiliser les flèches Tous les appareils Traulsen doivent être nettoyés avec de l’eau tiède, un vers le haut ou vers le bas pour accéder au paramètre suivant ou, savon doux et un chiffon souple.
  • Page 8: Dépannage

    Plaque signalétique Veuillez consulter notre site Web à www.traulsen.com pour de plus amples renseignements sur l’entretien et les pièces. Sur notre page d’accueil, cliquez sur l’onglet SERVICE & PARTS (Service et Pièces) et sélectionnez l’une des options suivantes : SERVICE FINDER (Rechercher de l’assistance technique)
  • Page 9: Manual Del Usuario

    Soporte para las series R y A y para la serie G (patas autoajustables) La mayoría de los equipos de Traulsen son de conexión y uso inmediato, como la serie G y la mayoría de los modelos compactos. Sin embargo, una vez que se suministra...
  • Page 10 II. OPERACIÓN: (continuación) Función de bloqueo de deshielo Gabinetes de conservación de alimentos calientes Los bloqueos de deshielo le permiten evitar que se ejecuten los ciclos de deshielo Todos se entregan en la posición de apagado. Para comenzar a usarse, presione durante dos horas en un período determinado.
  • Page 11 Todos los equipos de Traulsen deben limpiarse únicamente con agua tibia, jabón salir o desactivar durante 30 segundos. neutro y un paño suave. Limpie con un paño húmedo en el sentido de la veta del metal.
  • Page 12: Resolución De Problemas

    Placa de amperaje Visite nuestro sitio web en www.traulsen.com para obtener más información acerca del mantenimiento y las piezas. En la página de inicio de nuestro sitio web, haga clic en la pestaña SERVICE & PARTS (Servicio y piezas) y seleccione una de las opciones...