IV.
EXPOSURE
SYSTEM
2. Removing
the Thermal
Fuse
A. SCANNER
1. Removing
the Scanning
Lamp
1) Unplug the copier.
2) Remove the control
panel and copy-
board glass.
3) Unscrew the two screws and remove
the reflector.
1) Bemove
the control panel and copy-
board glass.
.--
2) Grasp the rear of mirror 1 mount move
,it to the right, and bring it to the part
shown in Figure 4-4 1.
Note:
Be sure to hold the rear of the mirror
1
mount at the rear when moving it.
3) Unscrew
the two
mounting
screws,
then remove the thermal fuse.
@
Screws
@ Reflector
Figure 4-39
4) Push the contact (rear) in the direction
of the arrow and remove the scanning
lamp.
@ Lamp contact
0
Scanning lamp
Figure 4-40
Note:
1. The scanning lamp will be hot, if it has
been operating recently.
2. Never touch the surface of the scanning
lamp, with bare hands.
3. If the scanning lamp is dirty, wipe it with
a dry cloth. If there are any fingerprints
or skin oil on it, clean them off with
solvent.
0
0
fvlounting screws @ Mirror 1 mount
Thermal fuse
Fiugre 4-41
4-
12
COPVRI6HT
0
I999
CANON INC.
CANON NP-1015/1215S
AN.0
OCT.
1999 PAINTEII
IN JAwlN llMPAlMf
AU JAPONI