Complete Calibration Summary

Calibration
What is calibrated
Mainframe
Accuracy and continuity
Calibration
of the timescale
Plug-in
Vertical o set and vertical
Vertical
scale accuracy.
Calibration
Dark
Dark calibration measures
Calibration
the channel o set signal
without any light present
and this value is used in
the extinction ratio
algorithm.
Probe
Probe Attenuation
calibration
Channel Skew Calibrates out the small
di erences in delay
between channels. Useful
for looking at timing
di erences between
channels
External Scale Compensates for gain or
loss associated with
external devices
(calibrates vertical scale
to external device)
3-14
Table 3-4. Complete Calibration Summary
Measurements A ected
Recommended Interval
All time base measurements
Annually at Agilent service
such as rise time, fall time,
center or if operating temp
eye width, and jitter.
has changed and remains
5

temperature. See service
manual.
Any electrical vertical
Perform after any power cycle
measurements such as
or once every 10 hours
V
, eye height,
during continuous use or if
p to p
extinction ratio
operating temperature
changes by more than 2
Channels a ected: electrical
Before extinction ratio
with O/E converter. Extinction
measurements if the vertical
ratio.
scale or o set has changed
since the last dark calibration
or after a plug-in vertical
calibration is performed.
Any electrical measurement
Whenever a probe is
taken with the probe
connected
Multiple channel
Before multiple channel
measurements
measurements when
measuring timing di erences
between channels.
Any measurement taken
Whenever using external
through an external device
devices (component or
(component or transducer)
transducer)
FINAL TRIM SIZE : 7.5 in x 9.0 in
Utility
4
FFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate frame
C or more from calibration
Utility
4
FFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate Plug-in
C.

Shift
4
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
Extinction ratio
FFFFFFFFFFFFFFFFFFFFFFFF
Dark Cal
Electrical Channel Setup
4
FFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate probe
Channel Setup
4
FFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
FFFFFFFFFFFFF
Skew
Channel Setup
4
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
External Scale
Key Path
5
5
,
Meas eye
5
4
5
5
5
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

834834a834834b83483a547512a547512b

Table of Contents