York YCAV0157 Installation Operation & Maintenance page 266

Air-cooled screw liquid chillers
Table of Contents

Advertisement

MICRO PANEL
SERVICE DO J10-1
RB1 TB1-20
SERVICE DO J10-2
RB1 TB1-18
SERVICE DO J10-3
RB1 TB1-16
SERVICE DO J10-4
RB1 TB1-14
SERVICE DO J10-5
RB1 TB1-12
SERVICE DO J10-6
RB1 TB1-10
SERVICE DO J10-7
RB1 TB1-8
SERVICE DO J10-8
RB1 TB1-6
SERVICE DO J10-9
RB1 TB1-5
SERVICE DO J10-10
RB1 TB1-4
SERVICE DO J10-11
RB1 TB1-3
SERVICE DO J10-12
RB1 TB1-2
SERVICE DO J11-1
RB1 TB1-20
SERVICE DO J11-2
RB1 TB1-18
SERVICE DO J11-3
RB1 TB1-16
SERVICE DO J11-4
RB1 TB1-14
SERVICE DO J11-5
RB1 TB1-12
266
SERVICE KEY (CON'T)
EVAP PUMP RUN
STATUS = XXX
SYS 2/4 VSD RUN
STATUS = XXX
SYS 2/4 ALARM
STATUS = XXX
CHILLER RUN
STATUS = XXX
SYS 2 SPARE
STATUS = XXX
SPARE 3
STATUS = XXX
SPARE 4
STATUS = XXX
SYS COND 2 FAN OUT 1
STATUS = XXX
SYS COND 2 FAN OUT 2
STATUS = XXX
SYS COND 2 FAN OUT 3
STATUS = XXX
SYS 2 COMP HEATER
STATUS = XXX
SYS 2 ECON SOL VALVE
STATUS = XXX
SYS 4 COND FAN OUT 1
STATUS = XXX
SYS 4 COND FAN OUT 2
STATUS = XXX
SYS 4 COND FAN OUT 3
STATUS = XXX
SYS 4 COMP HEATER
STATUS = XXX
SYS 4 ECON SOL VALVE
STATUS = XXX
SERVICE DO J11-6
RB1 TB1-10
SERVICE DO J11-7
RB1 TB1-8
SERVICE DO J11-8
RB1 TB1-6
SERVICE DO J11-9
RB1 TB1-5
SERVICE DO J11-10
RB1 TB1-4
SERVICE DO J11-11
RB1 TB1-3
SERVICE DO J11-12
RB1 TB1-2
The fifth data section displays the Analog Outputs
(AO) that can be viewed from the Service Mode. The
Analog Output signals are typically referenced to the
common (return, ground) in the system. J12-3 can also
be used as common, as well as chassis ground, or the
common terminal point on the Chiller Control Board.
See the wiring diagrams. GND on the plug. Displays
for systems 3 and 4 are skipped if the systems are not
present on the chiller. XXX is replaced with ON or OFF
in the actual display. The state of these outputs is only
viewable unless the password 9675 (ENTER) key was
entered from the initial Service Mode display with the
UNIT Switch in the OFF position. The chiller will not
be permitted to run when the outputs are made active.
The outputs can be programmed for a specific % output
by keying in the value and pressing the (ENTER) key.
These messages will only be displayed in English.
SERVICE AO J15-1
XXX.X %
SERVICE AO J15-3
XXX.X %
SERVICE AO J15-5
XXX.X %
SERVICE AO J15-7
XXX.X %
FORM 201.21-NM1 (1223)
SYS 4 SPARE
STATUS = XXX
SYS 3 SPARE
STATUS = XXX
SYS 3 COND FAN OUT 1
STATUS = XXX
SYS 3 COND FAN OUT 2
STATUS = XXX
SYS 3 COND FAN OUT 3
STATUS = XXX
SYS 3 COMP HEATER
STATUS = XXX
SYS 3 ECON SOL VALVE
STATUS = XXX
SYS 1 FEED VALVE OUT
= XX.X VDC
SYS 1 DRAIN VALVE OUT
= XX.X VDC
SYS 2 FEED VALVE OUT
= XX.X VDC
SYS 2 DRAIN VALVE OUT
= XX.X VDC
JOHNSON CONTROLS

Advertisement

Table of Contents
loading

Table of Contents