Table 53. Connection 1 Settings details (continued)
Option
Target Boot Lun
ISID
Authentication Type
CHAP Type
CHAP Name
CHAP Secret
Reverse CHAP Name
Reverse CHAP Secret
Table 54. TLS Authentication Configuration screen details
Option
TLS Authentication Mode
Root Certificate Configuration
Table 55. NVMe-oF SubSystem Settings screen details
Option
NVMe-oF SubSystemn (n = 1 to 4)
NVMe-oF SubSystemn Settings (n = 1
to 4)
Table 56. NVMe-oF SubSystem n Settings
Option
Interface
Transport Type
Protocol
VLAN
VLAN ID
VLAN Priority
Retry Count
Timeout
54
Pre-operating system management applications
Description
Shows the Target LUN for this iSCSI connection. The value format is a string containing a
hexadecimal-encoded representation of the 64-bit SCSI Logical Unit Number in the format
description in the T10 SCSI Architecture Model specification.
Enables ISID (Initiator Session ID) to use for this iSCSI connection. The value is 6 hexadecimal
numbers - such as 3ABBCCDDEEFF or 000000000000.
Specifies the authentication type for this ISCSI device connection. This option is set to None
by default.
Shows the CHAP type for this iSCSI connection. This option is set to One Way by default.
Shows the CHAP name for this iSCSI connection.
Shows the CHAP secret for this iSCSI connection.
Shows the Reverse CHAP name for this iSCSI connection.
Shows the Reverse CHAP secret for this iSCSI connection.
Description
View or modify the device's boot TLS Authentication Mode. This option is set to One
Way by default. None means the HTTP server and the client will not authenticate each
other for this boot.
Import, delete, or export the root certificate.
Description
Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Description
NIC interface used for NVMe-oF connections. This option is set to Embedded
NIC 1 Port 1 Partition 1 by default.
This field sets the value of transport type for NVMe-oF connection. This option is
set to TCP by default.
This field sets the value of protocol type for NVMe-oF connection. This option is
set to IPv4 by default.
Enables or disables VLAN for this NVMe-oF connections. This option is set to
Disabled by default.
Specifies the VLAN Id for this NVMe-oF connection. This option is set to 1 by
default.
Specifies the VLAN priority for this NVMe-oF connection. This option is set to 0 by
default.
Specifies the retry count for this NVMe-oF connection. This option is set to 3 by
default.
Specifies the time out for this NVMe-oF connection. This option is set to 10000 by
default.

Advertisement