SERVICE PROGRAM MODE
SP No. Mode
114
CLR RESETTABLE
COUNT
120
USER CODE MODE
3
121
UC COUNT
122
CLR UC COUNT
123
TOTAL UC COUNT
124
CLEAR TOTAL UC
COUNT
60
Function
Clears the resettable master/print counter.
Note
Default: 0
Adjustment value: 0: No 1: Yes
Selects user code mode. When you set this func-
tion, you have to also specify the auto reset time.
For details about user code mode, see ⇒ P.62 "Us-
er Codes".
Note
Default:
• User Code mode:0
• Auto Reset time: 0
Adjustment value:
• User Code mode: 0: No 1: Yes
• Auto Reset time: 0: No, 1 – 5 minutes
Displays the number of masters and prints made
in each user code.
Note
M: Number of masters
P: Number of prints
Clear each user code counter.
Note
Default: 0
Adjustment value: 0: No 1: Yes
Display the total number of masters and prints for
all the 20 user codes.
Note
M: Number of masters
P: Number of prints
Clear the total user code counter.
Note
Default: 0
Adjustment value: 0: No 1: Yes