Approved Vent Manufacturers - Jøtul GF 370 DV MV Installation And Operation Instruction Manual

Direct vent gas stove
Hide thumbs Also See for GF 370 DV MV:
Table of Contents

Advertisement

130102- 1 GF 370 DV MV 2/22
Stove and Vent Clearance
Requirements
Clearance is measured from the stove body as illustrated - not
the Safety Barriers.
Minimum Clearances:
See figs. 5.1-5.3.
Rear:
3" (76 mm) - from Rear of the unit
Ceiling:
16 3/4" (425 mm) - from Stove Top
Corner:
5" (127 mm) - from Stove Top
Sides:
7" (178 mm) - from Stove Top
Minimum Clearances from the Vent Pipe
to Combustibles:
Horizontal Run:
Off the top of the pipe - 2" (51 mm) Alcove - 7" (178 mm)
Off the sides and bottom - 1" (25 mm)
Vertical Run: All sides
7”
Figure 5.3. Alcove and Wall Clearances.
ALCOVE SPECIFICATIONS:
Maximum Alcove Depth:
Minimum Alcove Width:
Minimum Ceiling Height:
3”
Figure 5.4. Parallel Wall Clearances.
8
- 1" (25 mm)
15 5/8”
3”
12 3/4”
7”
21 3/4" (55.2 cm)
31 1/4" (79.3 cm)
62 1/4" (158.1 cm)
15 5/8”
12 3/4”
7”
6. Venting
Requirements
There are three types of venting configurations approved
for use with this appliance:
• Vertical Venting / Vertical Termination
• Vertical Venting / Horizontal Termination
• Horizontal Venting / Snorkel Termination
This appliance is approved for use with the 4/6 direct
vent systems manufactured by the companies listed on
page 8. Use parts of one manufacturer only - DO NOT
MIX VENT COMPONENTS FROM DIFFERENT
MANUFACTURERS WITHIN THE SAME SYSTEM.
Installation of any components not manufactured
or approved by Jøtul or failure to meet all clearance
requirements will void all warranties and could result in
property damage or bodily injury.
The approved vent configurations described in this
manual are derived from extensive testing under controlled
laboratory conditions. Gas appliance performance can be
negatively affected by variables present in the installation
environment, i.e.; atmospheric pressure, strong prevailing
winds, adjacent structures and trees, snow accumulation,
etc. These conditions should be taken into consideration
by the installer and stove owner when planning the vent
system design.

Approved Vent Manufacturers

The Jøtul GF 370 DV MV stove is approved for installation
with direct vent chimney components supplied by the
following manufacturers:
M&G DuraVent, Inc. (Direct Vent Pro Series)
P.O. Box 1510
Vacaville, CA 95696-1510
Selkirk Corporation
1301 W. President George Bush Hwy, Suite 330
Richardson, TX 75080-1139 800-992-8368
American Metal Products (Amerivent)
8601 Hacks Cross Rd.
Olive Branch, MS 38654
Security Chimneys International Limited
2125 Monterey, Laval, Québec
Canada, H7L 3T6
Metal-Fab, Inc. (Sure-Seal Direct Vent)
P.O. Box 1138
Wichita, KS 67201
ICC, Inc.
400 J-F Kennedy St. Jerome, Quebec
Canada, J7Y 4B7
Bernard Dalsin Manufacturing Co. (Pro Form)
5205 208th Street West
Farmington, MN 55024
Olympia Chimney Supply Inc.
600 Sanders Street Suite 2
Scranton, PA 18505-3400
800-835-4429
800-423-4270
450-973-9999
316-943-2351
450-565 6336
651- 460-1080
570-496-8890

Advertisement