Vent Requirements; Adding Restriction; Venting Requirements; Exhaust Restrictor - Jøtul GF 300 DV II Allagash Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

137775_Rev_K 7.29.10

Venting Requirements

The Jøtul GF 300 DV II gas stove may be installed with a
vertical or horizontal termination and must conform to
the configuration requirements described below.
This appliance is approved for use with vent systems
from the following manufacturers:
Simpson Dura-Vent GS
American Metal Products (Amerivent)
Security Chimneys International, Ltd. (Secure Vent)
Selkirk Metalbestos (Direct Temp)
Metal-Fab, Inc. (Direct Vent)
Industrial Chimney Corp. (ExcelDirect)
Use parts of one manufacturer only - DO NOT MIX
VENT COMPONENTS FROM DIFFERENT MANUFACTURERS
IN THE SAME SYSTEM.
Installation of any components not manufactured or
approved by Jøtul or failure to meet all clearance require-
ments will void all warranties and could result in property
damage, bodily injury, or serious fire.
The approved vent configurations described in this
manual are derived from extensive testing under con-
trolled laboratory conditions. Gas appliance performance
can be negatively affected by variables present in the
installation environment, i.e: atmospheric pressure, strong
prevailing winds, adjacent structures and trees, snow
accumulation, etc. These conditions should be taken into
consideration by the installer and stove owner when plan-
ning the vent system design.
• JOINT SEALING REQUIREMENT: APPLY A 1/8" BEAD OF
HIGH-TEMPERATURE SEALANT
OR MIL-PAC® TO THE MALE
SECTION OF THE INNER VENT
PIPE. THE CEMENT SHOULD
FORM A SEAL BETWEEN THE
INNER AND OUTER PIPES.
• NEVER MODIFY ANY VENT-
ING COMPONENT, OR USE
ANY DAMAGED VENTING
PRODUCT.
• THE GAS APPLIANCE AND
VENT SYSTEM MUST BE
VENTED DIRECTLY TO THE
OUTSIDE OF THE BUILDING
AND NEVER ATTACHED TO
A CHIMNEY SERVING A SOLID FUEL OR GAS BURNING
APPLIANCE. EACH DIRECT VENT GAS APPLIANCE MUST
HAVE ITS OWN SEPARATE VENT SYSTEM. COMMON
VENT SYSTEMS ARE PROHIBITED.
• IF VENTING SYSTEM IS DISASSEMBLED FOR ANY REA-
SON, REINSTALL PER THE INSTRUCTIONS PROVIDED FOR
THE INITIAL INSTALLATION.
8
IMPORTANT
Figure 5.
Vent Restriction
The GF 300 DV II is equipped with an Exhaust Restrictor
Plate which enables you to regulate the flow of exhaust
gas. The plate prevents overly strong draft that can cause
poor combustion and weak flame picture. Follow the
guidelines below, and on the following pages, to deter-
mine the correct restrictor plate setting for your particu-
lar installation configuration.

Exhaust Restrictor

The Exhaust Restrictor is an adjustable shutter located at
the top right side of the firebox. It is adjusted by mov-
ing a pivot pin into one of four positions. It is set in the
FULLY OPEN (D) position at the factory. See Fig. 7. The four
positions correlate to the termination zones (A,B,C,D)
diagramed in figures 9-12. Consult these Vent Window
diagrams on pages 10-11 to determine the setting you
should use.
Additional restriction may be needed depending the
overall vent height. If necessary, use Simpson Dura-Vent
Restrictor Disk #929 or a similar part from the appropri-
ate vent manufacturer.
Adjusting Exhaust Restrictor Plate:
1. Use the Vent Window diagrams to determine which set-
ting position to use.
2. Remove the Top Plate.
3. Locate the pivot pin at the right side of the firebox top.
Use a 7 mm or 9/32 nut driver to loosen the nut on the
pivot pin and then push the pin to the left to disen-
gage it from the current factory-set position. Move
the pin forward and into the slot appropriate for your
specific vent configuration. See figs. 6 and 7.
4. Tighten the lock nut and replace the Top Plate.