Multi functional protection ied

Advertisement

Setting
4.2.8
DPOS01(Function ID: 512001) at Change Over Switch
Setting items
Commo n
DPOS-NELD
DPOS-TELD
DPOS-TELR
DPOS01-EN
Dev01
DPOS01-DEVNAME
DPOS01-00NAME
DPOS01-01NAME
DPOS01-10NAME
DPOS01-11NAME
DPOS01-UDFNAME
DPOS01-FLTNAME
DPOS01-DEVTYPE
DPOS01A-NOPSG
DPOS01A-NOPSGI
DPOS01A-NCLSG
DPOS01A-NCLSGI
DPOS01B-NOPSG
DPOS01B-NOPSGI
DPOS01B-NCLSG
DPOS01B-NCLSGI
DPOS01C-NOPSG
DPOS01C-NOPSGI
DPOS01C-NCLSG
DPOS01C-NCLSGI
DPOS01-OPC
DPOS01-CLC
DPOS01-SPPEN
DPOS01-UDFEN
DPOS01-UDFTIM
DPOS01-FLTEN
DPOS01-FLTTIM
DPOS01-CTREN
DPOS01-CTRMENU
DPOS01-CTRAHMI
DPOS01-NSLBORD1
DPOS01-NSLBORD2
DPOS01-FSLBORD
DPOS01-OSLBORD
DPOS01-FEXBORD
DPOS01-OEXBORD
Range
Unit
0 - 99
- Number of Event lock detect time
1 - 99
s Timer of detect event lock
1 - 99
s Timer of recovery from event lock
Off / On
- DPOS01 switch for Device01
[Preferred text] - item name of DPOS_Dev1
[Preferred text] - state name of (0,0)state
[Preferred text] - state name of (0,1)state
[Preferred text] - state name of (1,0)state
[Preferred text] - state name of (1,1)state
[Preferred text] - state name of undefined
[Preferred text] - state name of faulty
1-Pole / 3-Pole /
- Device Type
switch
Normally Open Signal of the single-pole or
-
[Preferred signal]
phase A
Off / On
- Signal inverse or not
Normally Close Signal of the single-pole or
-
[Preferred signal]
phase A
Off / On
- Signal inverse or not
- Normally Open Signal of phase B
[Preferred signal]
Off / On
- Signal inverse or not
- Normally Close Signal of phase B
[Preferred signal]
Off / On
- Signal inverse or not
- Normally Open Signal of phase C
[Preferred signal]
Off / On
- Signal inverse or not
- Normally Close Signal of phase C
[Preferred signal]
Off / On
- Signal inverse or not
And / Or
- Normally Open contact grouping
And / Or
- Normally Close contact grouping
Off / On
- Automatic event suppression function
Off / On /
- undefined pallet check function
CHKONLY
0.1 - 100.0
s palette Undefined check timer
Off / On /
- faulty pallet check function
CHKONLY
0.1 - 100.0
s palette faulty check timer
Off / On
- control mode (control enable)
Off / On
- control by MENU enable
DIR / SBO
- control action(Direct or SBO)by HMI
select binary output read data(DataID)1 for no
-
[Preferred signal]
direction select command
select binary output read data(DataID)1 for no
-
[Preferred signal]
direction select command
select binary output read data(DataID) for off
-
[Preferred signal]
direction select command
select binary output read data(DataID) for on
-
[Preferred signal]
direction select command
execute binary output read data(DataID) for
-
[Preferred signal]
off direction execute command
execute binary output read data(DataID) for
-
[Preferred signal]
on direction execute command
- 548 -
Contents
6F2T0207 (0.01)
Default
Note
10
10
10
Off
DPOS_Dev1
!
Travelling0
!
Off
!
On
!
Travelling1
!
Undefine
!
Faulty
!
1-Pole
Not assigned
Off
Not assigned
Off
Not assigned
Off
Not assigned
Off
Not assigned
Off
Not assigned
Off
And
Or
Off
Off
30.0
Off
30.0
Off
Off
SBO
5120018903011DC0
5120018903011DC0
5120018A03011DC4
5120018603011DC6
Not assigned
Not assigned
GRE200 (5,6)