Table 12: ACX6160 DC Power Cable Specifications
Juniper Model Number
CBL-JNP-PWR-DSUB2 (right-angle cable)
CBL-JNP-PWR-DSUB3
(FT4 vertical-flame rated, right-angle cable)
WARNING: For field-wiring connections, use copper conductors only.
WARNING: Power cables must not block access to ACX6160 components or drape
where people could trip over them.
CAUTION: You must ensure that power connections maintain the proper polarity. The
power source cables might be labeled (+) and (–) to indicate their polarity. There is no
standard color coding for DC power cables. The color coding used by the external DC
power source at your site might be different from the color coding for the leads on the
DC power cable provided with the chassis.
RELATED DOCUMENTATION
ACX6160 Installation Overview | 47
Maintaining the ACX6160 Power Supplies | 71
(Continued)
Wire Function
Insulation Color
Ground
Green and yellow
–48 VDC input (–)
Blue
Return (+)
Black
–48 VDC input (–)
Gray
Return (+)
Gray
Wire Size
8 AWG (8.4 mm²), 90° C
8 AWG (8.4 mm²), 90° C
8 AWG (8.4 mm²), 90° C
8 AWG (8.4 mm²), 90° C
8 AWG (8.4 mm²), 90° C