Table Of Functions Of The Memory Switch - JUKI LK-1901AN Instruction Manual

Table of Contents

Advertisement

3. Table of functions of the memory switch
Various operations of sewing machine can be set in programs by operating the memory switches.
There are items that change the initial values at the time of delivery according to the models.
Indication
Max. sewing speed (Speed can
be set in a unit of 100 sti/min.)
Sewing speed of 1st stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 sti/min.)
Sewing speed of 2nd stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 sti/min.)
Sewing speed of 3rd stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 sti/min.)
Sewing speed of 4th stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 sti/min.)
Sewing speed of 5th stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 sti/min.)
Thread tension of 1st stitch
(With needle thread clamp)
Thread tension at the time of
thread trimming
Changeover timing of thread
tension at the time of thread
trimming
Sewing speed of 1st stitch
(Without needle thread clamp)
(Speed can be set in a unit of
100 sti/min.)
Sewing speed of 2nd stitch
(Without needle thread clamp)
(Speed can be set in a unit of
100 sti/min.)
Sewing speed of 3rd stitch
(Without needle thread clamp)
(Speed can be set in a unit of
100 sti/min.)
Sewing speed of 4th stitch
(Without needle thread clamp)
(Speed can be set in a unit of
100 sti/min.)
Sewing speed of 5th stitch
(Without needle thread clamp)
(Speed can be set in a unit of
100 sti/min.)
Thread tension of 1st stitch
(Without needle thread clamp)
Changeover timing of thread
tension at the sewing start
(Without needle thread clamp)
S e t t i n g w h e t h e r o r n o t
indication or change of X/Y
scale rate and max. speed
limitation is acceptable.
(Prevention of misapplication)
Function
Setting range
400 to 3200
400 to 1500
400 to 3200
400 to 3200
400 to 3200
400 to 3200
400 to 1500
400 to 3200
400 to 3200
400 to 3200
400 to 3200
0 : Operative
1 : Inoperative
State when delivered
3200
1500
3200
3200
3200
3200
0 to 200
200
0 to 200
0
-6 to 4
0
400
900
3200
3200
3200
0 to 200
0
-5 to 2
-5
0
42
Remarks
F o r L K - 1 9 0 3 A N a n d L K -
1900ANW set to 2700.
In case of setting 1, use of
M key is prohibited as well.
W h e n c h a n g i n g m e m o r y
switch, pressing M key, turn
ON the power switch.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lk-1902anLk-1903anLk-1903an-305