Table Of Functions Of The Memory Switch - JUKI LK-1900A Instruction Manual

Computer-controlled, high-speed, bartacking machine
Hide thumbs Also See for LK-1900A:
Table of Contents

Advertisement

3. Table of functions of the memory switch

Various operations of sewing machine can be set in programs by operating the memory switches.
There are items that change the initial values at the time of delivery according to the models.
Indication
Max. sewing speed (Speed can
be set in a unit of 100 rpm.)
Sewing speed of 1st stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 rpm.)
Sewing speed of 2nd stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 rpm.)
Sewing speed of 3rd stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 rpm.)
Sewing speed of 4th stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 rpm.)
Sewing speed of 5th stitch (With
needle thread clamp) (Speed can
be set in a unit of 100 rpm.)
Thread tension of 1st stitch (With
needle thread clamp)
Thread tension at the time of
thread trimming
Changeover timing of thread
tension at the time of thread
trimming
Sewing speed of 1st stitch
(Without needle thread clamp)
(Speed can be set in a unit of 100
rpm.)
13. Sewing speed of 2nd stitch
(Without needle thread clamp)
(Speed can be set in a unit of 100
rpm.)
Sewing speed of 3rd stitch
(Without needle thread clamp)
(Speed can be set in a unit of 100
rpm.)
Sewing speed of 4th stitch
(Without needle thread clamp)
(Speed can be set in a unit of 100
rpm.)
Sewing speed of 5th stitch
(Without needle thread clamp)
(Speed can be set in a unit of 100
rpm.)
Thread tension of 1st stitch
(Without needle thread clamp)
Changeover timing of thread
tension at the sewing start
(Without needle thread clamp)
Setting whether or not indication
or change of pattern No., X/Y
scale rate and max. speed
l i m i t a t i o n i s a c c e p t a b l e .
(Prevention of misapplication)
Function
Setting range
400 to 3000
400 to 1500
400 to 3000
400 to 3000
400 to 3000
400 to 3000
400 to 1500
400 to 3000
400 to 3000
400 to 3000
400 to 3000
0 : Operative
1 : Inoperative
State when delivered
3000
1500
3000
3000
3000
3000
0 to 200
200
0 to 200
-6 to 4
400
900
3000
3000
3000
0 to 200
-5 to 2
42
Remarks
For LK-1903A, set to 2700.
0
0
0
0
0
In case of setting 1, use of M key
is prohibited as well. When
changing memory switch,
pressing M key, turn ON the power
switch.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lk-1901aLk-1902aLk-1903aLk-1903a-305

Table of Contents