(2) Table of memory switch functions

Some initial values for shipment may change according to models.
The contents are divided into two categories of user level (U) and service level (S).
Indication
Level
U
Max sewing speed
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the first stitch
(with needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the second
stitch (with needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the third stitch
(with needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the 4th stitch
(with needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the 5th stitch
(with needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Thread tension for the first stitch
(with needle thread clamp)
U
Thread tension at the time of
thread trimming
U
Changeover timing of thread
tension at the time of thread
trimming
U
Sewing speed for the first stitch
(without needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the second
stitch (without needle thread
clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the third stitch
(without needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the 4th stitch
(without needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Sewing speed for the 5th stitch
(without needle thread clamp)
(Setting possible in the unit of
100 sti/min)
U
Thread tension for the first stitch
(without needle thread clamp)
U
Changeover timing of thread
tension at the sewing start (with-
out needle thread clamp)
U
Display of Pattern No., XY en-
largement/reduction scale rate,
and max. speed limits; change
enabled/disabled
Functions
Setting range
400 to 3200 sti/min
400 to 1500 sti/min
400 to 3200 sti/min
400 to 3200 sti/min
400 to 3200 sti/min
400 to 3200 sti/min
0 to 200
0 to 200
-6 to 4
(⁓ -1 : 32˚, 0 : 28˚, 1 : 24˚ ⁓)
400 to 1500 sti/min
400 to 3200 sti/min
400 to 3200 sti/min
400 to 3200 sti/min
400 to 3200 sti/min
0 to 200
-5 to 2
(⁓ -1 : 64˚, 0 : 60˚, 1 : 56˚ ⁓)
0 : Operative
1 : Inoperative
– 55 –
State when
Remarks
delivered
3200
To be set at 3000 for the LK-1901AN
and LK-1902AN.
To be set at 2700 for the LK-1900ANW
and LK-1903AN.
1500
3200
3200
3200
3200
200
0
0
When the setting value is increased,
operation becomes faster in the unit of
4˚.
400
900
3200
3200
3200
0
-5
When the setting value is increased,
operation becomes faster in the unit of
4˚.
0
In case of setting 1, use of M key is
prohibited as well. When changing
memory switch, pressing M key, turn
ON the power switch. (Standard opera-
tion panel)