Step 2: According to the difference between reference voltage and
receiving data in PCI-1712/1712L, adjust the gain, bipolar offset
and unipolar offset registers (Figure 6-14)
Step 3: Adjust the registers until they fall between the input voltage
from the standard voltage reference and the receiving voltage
reflectected in the Manual A/D Calibration tab.
Advantech Co., Ltd.
www.advantech.com
Get other manuals https://www.bkmanuals.com
Figure 6-14: Adjusting registers
– 65 –
PCI-1712/1712L User's Manual
Chapter 6