Download Print this page

Konica Minolta PCI-1712 Quick Start Manual page 37

1 ms/s, 12-bit, 16-ch highspeed multifunction card

Advertisement

same voltage. The difference between the ground voltages forms a
common-mode voltage (V
To avoid the ground loop noise effect caused by common-mode
voltages, you can connect the signal ground to the Low input. Figure
3-3 shows a differential channel connection between a ground-
reference signal source and an input channel on the PCI-1712/1712L.
With this connection, the PGIA rejects a common-mode voltage V
between the signal source and the PCI-1712/1712L ground, shown as
V
in Figure 3-3.
cm
Figure 3-3: Differential input channel connection - ground reference
If a floating signal source is connected to the differential input
channel, the signal source might exceed the common-mode signal
range of the PGIA, and the PGIA will be saturated with erroneous
voltage-readings. You must therefore reference the signal source
against the AIGND.
Figure 3-4 shows a differential channel connection between a floating
signal source and an input channel on the PCI-1712/1712L. In this
figure, each side of the floating signal source is connected through a
resistor to the AIGND. This connection can reject the common-mode
voltage between the signal source and the PCI-1712/1712L ground.
Advantech Co., Ltd.
www.advantech.com
Get other manuals https://www.bkmanuals.com
).
cm
signal source
– 25 –
PCI-1712/1712L User's Manual