APPENDIX D
PCI-1712/1712L User's Manual
output of its previous counter, i.e. counter 2, whose gate
source in turn comes from counter 1, whose gate source
comes from counter 0, etc.
[Gn1: Gn0] = [1, 0], External gate is on connector
CNTn_GATE (n = 0, 1, 2).
[Gn1: Gn0] = [1, 1], this mode is for pulse width measure
ment only.
This bit specifies whether the gate polarity is positive or
negative. "0" means the gate polarity is positive; "1" means
the gate polarity is negative.
When [Gn1: Gn0] = [0, 0], which means the counter gate is
set by GQn through software.
For example, you can write 0 to GQN to set gate input of
counter n as logic low or write 1 to set it as logic high.
Pulse width measurement state machine just allows one
positive cycle to pass. Please use rising-edge signal to reset
the pulse width measurement state machine before the
measured signal input.
This bit is read-only and shows the counter's GATE status.
"1" means the gate input of counter n is logic-high; "0"
means the gate input of counter n is logic low.
This bit is read-onlyand shows the counter's OUT status.
"1" means the OUT of counter n is logic-high; "0" means
logic low.
This bit is read-only and shows the counter's CLK status.
"1" means the CLK of counter n is logic-high; "0" means
logic low.
– 98 –