4.2.9 Load pattern selection (Pr. 14)

" Load pattern selection (Pr. 14)
Pr. 14 "load pattern selection"
You can select the optimum output characteristic (V/F characteristic) for the application
and load characteristics.
Parameter
Factory
Number
Setting
14
Pr.14=0
For constant-torque loads
(e.g. conveyor, cart)
100%
Output
voltage
Base frequency
Output frequency (Hz)
Pr.14=2
For lift
Boost for forward rotation...Pr. 0 (Pr.46) setting
Boost for reverse rotation...0%
100%
Forward
Output
rotation
voltage
Reverse
Pr.0
rotation
Pr.46
Base frequency
Output frequency (Hz)
Note: 1. This parameter setting is ignored when the general-purpose magnetic flux
vector control mode has been selected.
2. Pr. 46 "second torque boost" is made valid when the RT signal turns on.
The RT signal acts as the second function selection signal and makes the
other second functions valid.
Refer to page 118 for Pr. 180 to Pr. 183 (input terminal (DeviceNet input)
function selection).
Pr. 18 &
& Refer to Pr. 1, Pr. 2.
& &
Pr. 19 &
& &
& Refer to Pr. 3.
Pr. 20, Pr. 21 &
& Refer to Pr. 7, Pr. 8.
& &
Setting
Range
0
0 to 3
71
Get other manuals https://www.bkmanuals.com
PARAMETERS
Related parameters
Pr. 0 "torque boost"
Pr. 46 "second torque boost"
Pr. 80 "motor capacity"
Pr. 180 to Pr. 183
(input terminal (DeviceNet input)
function selection)
Pr.14=1
For variable-torque loads
(Fan, pump)
100%
Output
voltage
Base frequency
Output frequency (Hz)
Pr.14=3
For lift
Boost for forward rotation...0%
Boost for reverse rotation...Pr. 0 (Pr.46) setting
100%
Reverse
Output
rotation
voltage
Forward
Pr.0
rotation
Pr.46
Base frequency
Output frequency (Hz)