2.1 Installation

2 INSTALLATION AND WIRING

2.1 Installation

2.1.1 Instructions for installation

When mounting any of the FR-E520-0.1KND to 0.75KND, remove the accessory cover,
front cover and wiring cover.
1) Handle the unit carefully.
The inverter uses plastic parts. Handle it gently to protect it from damage.
Also, hold the unit with even strength and do not apply too much strength to the front
cover alone.
2) Install the inverter in a place where it is not affected by vibration easily (5.9m/s
maximum).
Note the vibration of a cart, press, etc.
3) Note on ambient temperature.
The inverter life is under great influence of ambient temperature. In the place of
installation, ambient temperature must be within the permissible range -10°C to
+50°. Check that the ambient temperature is within that range in the positions shown
in figure 3).
4) Install the inverter on a non-combustible surface.
The inverter will be very hot (maximum about 150°C). Install it on a non-combustible
surface (e.g. metal). Also leave sufficient clearances around the inverter.
5) Avoid high temperature and high humidity.
Avoid direct sunlight and places of high temperature and high humidity.