2.2 Wiring

2.2 Wiring

2.2.1 Terminal connection diagram

" " " " 3-phase 200V power input
NFB
3-phase AC
power supply
Output stop
Reset
Sink input
commons
Source input
commons
Control input signals
(no voltage input allowed)
DeviceNet communication signals
V+
CAN+
SHLD
CAN-
V-
DeviceNet
master unit
Note: 1. 0.1K and 0.2K do not contain a transistor.
2. Terminals SD and P24 are common terminals. Do not connect them to each
other or to the earth.
MC
(L
)
R
1
S
(L
)
2
T
(L
)
3
MRS
RES
SD
(Note 2)
SD
P24
(Note 2)
P24
×10
SW1 SW2
V+
Node address
CAN+
SHLD
CAN-
V-
NC
Sink/source
(Indicator)
POWER LED
ALARM LED
L.RUN LED
PU connector
(RS-485)
Get other manuals https://www.bkmanuals.com
INSTALLATION AND WIRING
U
V
W
Jumper
P1
Remove this jumper when
(+)P
using the optional power-factor
improving DC reactor.
PR
(−)N
Brake resistor connection
(Note 1)
A
B
Alarm
output
C
×1
setting
SINK
SOURCE
changing
Ground
11
Motor
IM
Ground
Main circuit terminal
Control circuit input terminal
Control circuit output terminal