• S.68005: [S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal
Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please
check error logs for the presence of additional downstream device error data.
[S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error Status
register contains %. The Global Non-Fatal Error Status register contains %. Please check error logs for
the presence of additional downstream device error data.
Severity: Error
User Response:
Complete the following steps:
1. Check log for a separate error for an associated PCIe device and service that error.
2. Check IBM Support website for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. (Trained service technician only) Replace the system board.
• W.11004: [W.11004] A processor within the system has failed the BIST.
[W.11004] A processor within the system has failed the BIST.
Severity: Warning
User Response:
Complete the following steps:
1. If the Processor or firmware was just updated, check IBM Support website for an applicable service
bulletin or firmware update that applies to this Processor error.
2. (Trained service technician only) If there are multiple Processor's, swap Processor's to move affected
Processor to another Processor socket and retry. If problem follows the affected Processor, or this is
a single Processor system, replace the Processor. Inspect Processor socket on each Processor
removal and replace system board first if damaged or mis-aligned pins are found.
3. (Trained service technician only) Replace the system board.
• W.3048006: [W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot
Recovery (ABR) event.
[W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event.
Severity: Warning
User Response:
Complete the following steps:
1. Check IBM Support website for an applicable service bulletin or firmware update that applies to this
error.
2. Reflash Primary UEFI image. Refer to UEFI Recovery section of service information for this product.
3. (Trained service technician only) Replace the system board.
• W.305000A: [W.305000A] An invalid date and time have been detected.
[W.305000A] An invalid date and time have been detected.
Severity: Warning
User Response:
Complete the following steps:
Appendix B. UEFI/POST diagnostic codes
541