• 80070219-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (SysBrd Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702190701ffff or 0x800702190701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check for an error LED on the system board.
2. Check the system-event log.
3. Check for the system firmware version and update to the latest version. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
4. Unplug and restore AC power cord, then, perform step 1 and 2 again.
5. If problems still occurred, (trained technician only) replace the system board.
• 80070301-0301ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state. (CPU 1 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
May also be shown as 800703010301ffff or 0x800703010301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0524