Download Print this page

Installing The Valve - Toro 08781 Operator's Manual

Rear remote hydraulic kit
Hide thumbs Also See for 08781:

Advertisement

6

Installing the Valve

Parts needed for this procedure:
1
Valve
2
Bolt (1/4 x 3 inches)
2
Nut (1/4 inch)
1
Small 90-degree elbow
1
Tee fitting
1
Relay
Procedure
Note:
Make sure that all O-rings are lubricated and
properly positioned on all fittings before installation.
Note:
Install all fittings and hydraulic lines loosely first
and then tighten them when everything is installed.
Install the fittings at the angles shown in the figures.
1.
Install the fittings at the angles shown in the
figures. Install the tee fitting to the side of the
new valve; refer to
2.
Install a small 90-degree elbow to the top of the
new valve
(Figure
3.
Remove the existing valve from the valve
bracket
(Figure
12).
4.
Install the relay to the valve bracket at the same
time the valves are installed to the valve bracket.
5.
Install the valves to the valve bracket with 2
bolts (1/4 x 3 inches) and 2 nuts (1/4 inch); refer
to
Figure
12.
Figure
12.
12).
1. Valve bracket
2. Tee fitting
3. Small 90-degree elbow
4. Bolt (1/4 x 3 inches)
7
Installing Hydraulic Lines
1, 2, and 5
Parts needed for this procedure:
1
Hydraulic line number 1
1
Hydraulic line number 2
1
Hydraulic line (hose) number 5
Procedure
Use
Figure 13
for identifying the correct hydraulic
lines.
8
Figure 12
5. Existing valve
6. New valve
7. Relay
8. Nut (1/4 inch)
g363211

Advertisement

loading