Heat & Glo 6000CL-IFT-S Owner's Manual
Hide thumbs Also See for 6000CL-IFT-S:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See appliance installation manual for additional
Commonwealth of Massachusetts requirements.
Owner's Manual
Heat & Glo • 6000CL-IFT, 8000CL-IFT Owner's Manual • 2504-981 Rev. K • 12/20
Care and Operation
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000CL-IFT-S

  • Page 1 Owner’s Manual Care and Operation INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. Contact your dealer with questions regarding installation, operation or service. NOTICE: DO NOT discard this manual! WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or...
  • Page 2: Welcome

    Welcome Read this manual before operating this appliance. Please retain this Owner’s Manual for future reference. Read the Installation Manual before making any installation or finishing changes. A. Congratulations This owner’s manual should be retained for future reference. We suggest that you keep it with your other Congratulations on selecting a Heat &...
  • Page 3: Table Of Contents

    Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. •...
  • Page 4: Limited Lifetime Warranty

    B. Limited Lifetime Warranty  Hearth & Home Technologies LLC LIMITED LIFETIME WARRANTY Hearth & Home Technologies LLC (“HHT”) extends the following warranty for HHT gas, wood, pellet and electric hearth appliances (each a “Product” and collectively, the “Product(s)”) and certain component parts set forth in the table below (“Component Part(s)”) that are purchased from a HHT authorized dealer or distributor.
  • Page 5 B. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: • Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers is available on the HHT branded websites.
  • Page 6: Product Specific Information

    Product Specific Information A. Appliance Certification B. Glass Specifications This appliance is equipped with 5 mm ceramic glass. Re- MODELS: 6000CL-IFT-S, 6000CL-IFTLP-S, place glass only with 5 mm ceramic glass. Please contact 6000CL-IFT-G, 6000CL-IFTLP-G, your dealer for replacement glass. 8000CL-IFT-S, 8000CL-IFTLP-S, 8000CL-IFT-G, 8000CL-IFTLP-G C.
  • Page 7: Important Safety And Operating Information

    Important Safety and Operating Information A. Appliance Safety • Teach children to NEVER touch the fireplace. WARNING! DO NOT operate fireplace before reading • Consider not using the fireplace when children will be and understanding operating instructions. Failure present. to operate fireplace according to operating instructions Contact your dealer for more information, or visit: www.
  • Page 8: General Operating Parts

    B. General Operating Parts D. Good Faith Wall Surface/TV Guidelines Figure 3.2 references the general operating parts of the FIREPLACE appliance and the section of this manual in which they are OPENING TO CEILING discussed. 127°F 123°F 132°F 30 in. 135°F 24 in.
  • Page 9 Good Faith Guidelines for TV Installa�ons Above Appliance TV recessed into the wall TV on the wall TV Wall Bracket Item Minimum Dimensions 2.5 inches 2 inches minimum to 3 inches maximum 18 inches Wall Brkt + TV Thickness + 2.5 inches Mantel Appliance...
  • Page 10: Before Lighting Appliance

    E. Before Lighting Appliance Before operating this fireplace for the first time, have a qualified service technician: • Verify all shipping materials have been removed from inside and/or underneath the firebox. • Review proper placement of logs, ember material and/or other decorative materials.
  • Page 11: Lighting Instructions (Ipi)

    F. Lighting Instructions (IPI) Heat & Glo • 6000CL-IFT, 8000CL-IFT Owner’s Manual • 2504-981 Rev. K • 12/20...
  • Page 12: Appliance Break-In

    G. Appliance Break-In H. Heat Management Follow the initial break-in procedure below to cure the Heat Output materials used to manufacture the fireplace and the • Heat output may be controlled on these models by finishing materials around it. adjusting the “Flame Height” setting on the remote •...
  • Page 13: Operation During A Power Outage - Intellifire Touch

    I. Operation During A Power Outage - IntelliFire Touch ® To Return to Operation Using Electrical (AC) Power The IntelliFire Touch intermittent pilot ignition system comes with a battery backup system that enables the Standard Wall Switch or Factory-Installed ON/OFF system to operate in a power outage.
  • Page 14: Detailed Component Operating Instructions

    J. Detailed Component Operating 3. The Pilot button on the IFT-ECM activates the Cold Climate function of the fireplace. This function lights Instructions - IntelliFire Touch the pilot flame ONLY to provide enough heat in the IFT-ECM Detailed Operating Instruction firebox to reduce condensation in cool, high humidity This model is shipped from the factory equipped with the ambient conditions.
  • Page 15 LED Accent Lighting IntelliFire Touch Ignition System • LED accent lighting is a standard feature on the 6000CL-IFT-S and 8000CL-IFT-S models. NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before • The intensity of the these lights may be controlled...
  • Page 16: Maintenance And Service

    Maintenance and Service B. Maintenance Tasks - Homeowner Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace. Installation and repair should be done by a qualified service technician only. The appliance should be inspected before When properly maintained, your fireplace will give you use and at least annually by a professional service person.
  • Page 17 Glass Cleaning Replacing Fixed Glass Assembly • Replace the glass assembly on the appliance. Pull out Frequency: Seasonally and latch the four glass assembly latches into the groove By: Homeowner on the glass frame. Tools Needed: Protective gloves, glass cleaner, drop •...
  • Page 18: Maintenance Tasks - Qualified Service Technician

    Burner Ignition and Operation C. Maintenance Tasks - Qualified Service Technician Frequency: Annually The following tasks must be performed by a qualified ser- By: Qualified Service Technician vice technician. Tools needed: Protective gloves, vacuum cleaner, whisk Gasket Seal and Glass Assembly Inspection broom, flashlight, voltmeter, indexed drill bit set, and a manometer.
  • Page 19 LED Accent Lighting Black Glass Refractory (6000CL-IFT-S and 8000CL-IFT-S models only) Frequency: Annually Frequency: As needed By: Qualified Service Technician Tools needed: Protective gloves, dust cloths, non-abra- By: Qualified Service Technician sive glass cleaner Tools needed: Protective gloves, replacement LED as- semblies, 1/4 inch nut driver.
  • Page 20 Refractory, Grate and Valve Assembly Re- moval It may become necessary to remove the refractory, grate and valve assemblies. This task should be performed by a qualified service technician. The refractory, grate and base refractory do not need to be removed to service the burner assembly.
  • Page 21 Note: The base refractory must be removed to access screws. BASE REFRACTORY Figure 4.7 Valve Assembly Removal Burner Identification/Verification The burner may be accessed for identification and veri- fication purposes. This task should be performed by a qualified service technician. The base refractory, valve plate, refractory panels and grate do not need to be re- moved to access the burner assembly.
  • Page 22: Frequently Asked Questions And Troubleshooting

    Frequently Asked Questions and Troubleshooting A. Frequently Asked Questions - Appliance ISSUE SOLUTIONS This is a result of gas combustion and temperature variations. As the fireplace warms, this Condensation on the glass condensation will disappear. This is a result of normal operation and the flames will begin to yellow as the fireplace is al- Blue flames lowed to burn for 20 to 40 minutes.
  • Page 23: Frequently Asked Questions - Intellifire Touch Controls (Ift-Rc400)

    B. Frequently Asked Questions - IntelliFire Touch Controls (IFT-RC400) Symptom Possible Cause Corrective Action The appliance does not respond to Batteries are depleted. Verify batteries are new. commands from the remote control display does not light up when Batteries are incorrectly Verify batteries are installed in correct orientation as shown on screen is touched.
  • Page 24: Troubleshooting

    C. Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Contact your dealer to arrange a service call by a qualified service technician.
  • Page 25 IntelliFire Touch - (continued) Symptom Possible Cause Corrective Action Verify incoming gas line ball valve is ‘Open’. Verify inlet No gas supply. pressure is within requirement for gas type used. Contact gas supplier. Pilot sparks but does not light, after Verify wiring, check valve harness black wire is securely ECM has poor ground.
  • Page 26: Reference Materials

    Reference Materials A. Accessories Install approved accessories per instructions included with accessories. Contact your dealer for a list of ap- proved accessories. WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty.
  • Page 27: Service Parts

    6000CL-IFT-G, 6000CL-IFT-S B. Service Parts Service Parts Beginning Manufacturing Date: Mar 2018 36” Gas Fireplace - DV Ending Manufacturing Date: Active Log Set Assembly 10.1 10.2 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Stocked Home Technologies does not sell directly to consumers.
  • Page 28 8000CL-IFT-G, 8000CL-IFT-S Service Parts Beginning Manufacturing Date: Mar 2018 Ending Manufacturing Date: Active Log Set Assembly 10.1 10.2 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Stocked Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 29 SRV2326-152 Component Tray 2279-180 18.19 LED Controller, (Only for the -S) 2166-336 Orifice, NG #33C 582-833 6000CL-IFT-S/-G Orifice, Propane #51C 582-851 Orifice, NG #31C SRV582-831 8000CL-IFT-S/-G Orifice, Propane #49C SRV582-849 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 3A fuse, 3/4” long Additional service part numbers on following page.
  • Page 30 Contains: Vent, Burner Neck, Valve, LED, and Adjustable Air Shutter Gaskets Glass Latch Assembly Qty 4 req 2155-045 Mineral Wool 050-721 Refractory Kit Black Glass , 6000CL-IFT-G SRV2506-079 Top Refractory SRV2506-713 Refractory Kit Stratford, 6000CL-IFT-S SRV6CLXREF-STRT Back Refractory SRV2166-710 Left Refractory SRV2166-711 Right Refractory SRV2166-712 Top Refractory SRV2166-713...
  • Page 31: Contact Information

    C. Contact Information Heat & Glo, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 www.heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com.

Table of Contents