Heat & Glo 6000CLX-IPI-T Owner's Manual
Hide thumbs Also See for 6000CLX-IPI-T:
Table of Contents

Advertisement

Models:
6000CLX-IPI-T
6000CLX-IPILP-T
6000CLX-IPI-S
6000CLX-IPILP-S
8000CLX-IPI-T
8000CLX-IPILP-T
8000CLX-IPI-S
8000CLX-IPILP-S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000CLX-IPI-T

  • Page 1 See Table of Contents for location of additional Commonwealth of Massachusetts requirements. gases, unless a certifi ed kit is used. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 2: Congratulations

    00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 3: Table Of Contents

    F. Wall Switch Installation for Fan ....51 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 4 D. Contact Information ......86  = Contains updated information. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 5: Limited Lifetime Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 7: Listing And Code Approvals

    CANADA 36,000 18,900 (2000-4500 FT) 45,000 22,000 (0-2000 FT) 8000CLX-IPI (NG) CANADA 40,500 19,800 (2000-4500 FT) 45,000 23,000 (0-2000 FT) 8000CLX-IPILP CANADA 40,500 20,700 (2000-4500 FT) Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 9: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. GRATE • Keep remote controls out of reach of children. SECTION 3.C. Figure 2.1 General Operating Parts Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 10: Fan Kit

    For more information refer to the instructions supplied with your decorative decorative front. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 11: Ipi Battery Tray/Battery Installation

    Batteries should only be installed for use during power WARNING! Risk of Fire or Asphyxiation! DO NOT op- outages. See Section H. erate fi replace with fi xed glass assembly removed. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 12: For Your Safety Read Before Lighting

    Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 13: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 14: Maintenance And Service

    • Inspect draft shield to verify it is not damaged or missing. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall decorative front. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 15: Maintenance Tasks-Qualifi Ed Service Technician

    (Either cobrahead or SIT) • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 16: Refractory, Grate And Valve Assembly Removal

    NOTICE: Remove refractory before removing grate. If grate is removed fi rst, damage to refractory will occur. Figure 3.4 Grate Removal Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 17: Burner Identifi Cation/Verifi Cation

    NOTCH LOCATION BURNER BOTTOM BURNER BOTTOM 6000C 6000CL 6000CLX 6000CBV Note: Notch location may vary by model. 8000C 8000CL 8000CLX 8000CBV Figure 3.7 Burner Identifi cation Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 18: Installer Guide

    IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH SECTION 12.C. MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 19: Design And Installation Considerations

    Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 20: Framing And Clearances

    Mantel Projections 1295 1067 1829 1438 55-7/8 61-1/2 19-3/4 See Section D. 8000 Mantel Projections 1419 1245 2007 1562 Figure 5.1 Appliance Locations - 6000 Models Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 21: Constructing The Appliance Chase

    * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 22: Mantel And Wall Projections

    Note: All measurements in inches. Note: Measurement is taken from top of the opening, NOT the top of the fi replace. Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 23: Termination Locations

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 24 2 sides beneath the fl oor. venting system does not meet these requirements. Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 25: Vent Information And Diagrams

    DVP12 Length DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 26: Vent Diagrams

    90º elbow, to allow the vent pipe to clear the top standoffs. Figure 7.3 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 27 = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum = 20 ft. (6.1 m) Maximum = 1 ft. (305 mm) Minimum INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 28 16 ft * 4.9 m* 4 ft. 1.2 m 16 ft.* 4.9 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 7.5 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 29 2. Break the fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8). BREAK HERE Figure 7.8 Flue Restrictor Figure 7.6 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 30 20 ft. 6.1 m = 50 ft. (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 7.11 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 31 = 40 ft. (12.2 m) Maximum * No specifi c restrictions on this value EXCEPT V cannot exceed 40 ft. (12.2 m). INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 32: Rear Vent - Horizontal Termination

    8000CLX 12 in. (305 mm) Figure 7.13 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.14 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 33 20 ft. 6.1 m INSTALLED = 40 ft. (12.2 m) Maximum = 3 ft. (914 mm) Maximum HORIZONTALLY = 20 ft. (6.1 m) Maximum Figure 7.16 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 34 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m = 40 ft. (12.2 m) Maximum = 15 ft. (4.6 m) Maximum INSTALLED HORIZONTALLY Figure 7.18 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 35 = 40 ft. (12.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED Figure 7.20 HORIZONTALLY Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 36: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 37: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 38: Installing The Optional Heat-Zone Gas Kit

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone ® Gas kit instructions for the remaining installation steps. HEAT-ZONE ® ATTACHES HERE Figure 8.5 Heat-Zone Knockout ® Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 39: Appliance Preparation

    Figure 9.5 Remove the insulation from the outer vent pipe. For rear venting there is no insulation in the outer vent pipe. Figure 9.3 Remove the seal cap. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 40: Rear Vent

    (90º) and remove the insulation gasket. Figure 9.10 Discard the vent cap, remove and discard the insulation basket. Figure 9.8 Cut the metal retaining band and fold the sides out. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 41: Installing The Non-Combustible Board

    • Bend out nailing tabs on each side. Figure 9.14 Proper Positioning and Securing of an Appliance • Place the appliance into position. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 42: Installing Vent Pipe (Dvp And Slp Pipe)

    Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 43: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 44: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 45: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. Figure 10.13 WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 46: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 47: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.18. Figure 10.18 Wall Thimble Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 48: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 49: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 50: Electrical Information

    LED CONTROL ORANGE GREEN (PILOT) (MAIN) GROUND BATTERY PACK 6V DC REAR ACCENT LIGHTING (X 2) FRONT EMBER LIGHTING (X 3) Figure 12.1 IPI Wiring Diagram Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 51: Electrical Service And Repair

    (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 52: Finishing

    2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Inches Millimeters  Inches  Millimeters Figure 13.2 Clearances to Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 53: Decorative Fronts

    They must be removed following fi n- ishing work. See Figure 13.7. Figure 13.4 Finishing Material 1 Inch Thick or Less Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 54 B = Top of decorative front to bottom of fi replace. D = Bottom of Finishing Material to Bottom of Fireplace Figure 13.5 Finishing Material Thickness Greater Than One Inch Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 55 Figure 13.7 Removing Finishing Strips. 31-7/8 IN. (6000) 33-11/16 IN. (8000) 3-3/4 IN. (6000, 8000) 35-5/16 IN. (6000) 43 IN. (8000) Figure 13.8. Clean Face Decorative Front Dimensions Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 56: Elevated Hearth Systems

    Note 1. Add dimensions to Wall Penetration (Figure 8.2) and Rough Opening Height (Figure 5.2). Note 2. Verify Marble Cut Lengths on site prior to cutting. Note 3. Dimensions assume use of a 3/4 in. Hearth Pad. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 57: Appliance Setup

    BEND TABS UP AIR SCOOP PILOT COVER BURNER ASSEMBLY BURNER SHIELD GUIDE SLEEVES Figure 14.1 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 58: Refractory Installation

    fi rebox lip. Let refractory foot rest on fi rebox af- ter panel’s notch has been mated with fi rebox lip. See Figure 3. Figure 5 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 59: Ember Placement

    fi t together and gaps should be minimized with correct installation. NO GAPS NO GAPS Figure 14.3 Embers Overlapping Burner Port Holes (LP only). Figure 7 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 60: Teco-Sil Placement

    • Fog the Teco-Sil to create a realistic coal bed appear- ance. NOT PAINTED NOT PAINTED Figure 14.5 Teco-Sil Not Painted TOO LIGHT TOO LIGHT Figure 14.6 Teco-Sil Too Light Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 61: Install The Log Assembly

    fi tted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine. See Figure 7. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 62 AREA LOCATING LOCATING NOTCH NOTCH LOG CONTACTS GRATE TINES LOG CONTACTS GRATE TINES LOG CONTACTS GRATE TINE LOG CONTACTS GRATE TINE Figure 12 Figure 11 2183-935C Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 63 fi tted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 64 Log #7 to the right until the notch of Log #7 contacts the grate tine located 4th from the left as shown in Figure 11. 2170-945C LOG CONTACTS GRATE TINE LOG CONTACTS GRATE TINE Figure 11 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 65: Fixed Glass Assembly

    • Install optional trim kits and/or surrounds using the instructions included with the accessory. • Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model). Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 66: Troubleshooting

    Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 67 fl ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 68: Reference Materials

    Inches Millimeters 1041 11-11/16 36-1/8 33-1/2 28-1/2 14-1/4 34-5/8 2-1/4 8-1/2 2-7/8 9-11/16 26-7/8 8-1/2 6 dia. 39-7/8 1013 40-7/8 1038 Figure 16.1 Appliance Dimensions-6000 Models Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 69 Location Inches Millimeters 1219 11-11/16 43-1/8 1096 35-1/2 35-1/2 17-3/4 36-5/8 2-3/8 8-1/2 2-7/8 9-15/16 8-1/2 28-7/8 42-7/8 1089 41-7/8 1064 Figure 16.2 Appliance Dimensions-8000 Models Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 70 1-1/4 7-11/16 32-7/8 34-1/16 6000 ARC-36 39-7/16 22-7/16 44-1/16 1-1/4 7-7/16 34-13/16 8000 ARC-42 1002 1119  Figure 16.3 Decorative Front Dimensions - Folio and Arcadia Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 71 1-1/2 7-7/8 32-7/8 34-1/8 6000 CHA-36 22-7/16 39-7/16 44-1/16 1-1/4 7-7/16 34-13/16 8000 CHA-42 1002 1119  Figure 16.4 Decorative Front Dimensions - Halston and Chateau Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 72 1-1/4 7-3/4 32-7/8 34-1/16 6000 GALLERIA-6 38-9/16 22-3/4 44-1/16 1-1/4 7-3/4 34-3/4 8000 GALLERIA-8 1121 Figure 16.5 Decorative Front Dimensions - Chateau Forge and Galleria  Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 73 35-13/16 4-5/8 6-15/16 26-3/4 31-7/16 6000 CF-36 38-1/2 24-1/16 42-3/4 4-5/8 6-15/16 28-11/16 33-5/16 8000 CF-42 1086  Figure 16.6 Decorative Front Dimensions - Clean Face Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 74: Vent Components Diagrams

    (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.7 DVP Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 75 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.8 DVP Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 76 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.9 DVP Vent Components Cap Shield Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 77 (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP High Performance Cap Figure 16.10 DVP Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 78 13-5/8 in. 16-11/16 in. 16-11/16 in. (346 mm) (424 mm) 424 mm 12-1/2 in. (318 mm) SLP-LPC SLP Low Profi le Cap Figure 16.11 Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 79 1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.12 SLP Series Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 80 DVP-2SL Extended Heat Shield Adapter 14-7/16 in. 367 mm 2-5/16 in. 14-7/16 in. 59 mm 367 mm SLP-WT-BK Wall Thimble-Black Figure 16.13 SLP Series Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 81 28-1/2 in. 724 mm 12-1/2 in. 318 mm 13-1/2 in. 343 mm SLK-SNKD SLP-TVHW Snorkel Vertical Termination Cap Termination Cap Figure 16.14 SLP Series Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 82: Service Parts

    Sold as set only Finishing Strips SRVFS-6 Blower GFK-160A Junction box 4021-013 Ember Mesh 2166-113 Flue Restrictor 385-128 Surround 2166-019 Additional service part numbers on following page. 11/14 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 83 Sold as set only SRVFS-8 Blower GFK-160A Junction box 4021-013 Ember Mesh 2166-113 Flue Restrictor 385-128 Surround 2170-019 Additional service part numbers on following page. 11/14 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 84 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 1A fuse, 3/4" long Additional service part numbers on following page. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 85: Service Parts

    LPKI-6CLX Conversion Kit NG NGKI-8CLX 8000CLX-IPI Conversion Kit LP LPKI-8CLX Pilot Orifi ce, NG 593-528 Pilot Orifi ce, LP 593-527 Regulator, NG NGK-DXV-50 Regulator, LP LPK-DXV-50 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...
  • Page 86: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2014 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AG • 11/14...