Heat & Glo 6000CLX-IPI-T Owner's Manual

Heat & Glo 6000CLX-IPI-T Owner's Manual

Fireplace
Hide thumbs Also See for 6000CLX-IPI-T:
Table of Contents

Advertisement

Models:
6000CLX-IPI-T
6000CLX-IPILP-T
6000CLX-IPI-S
6000CLX-IPILP-S
8000CLX-IPI-T
8000CLX-IPILP-T
8000CLX-IPI-S
8000CLX-IPILP-S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000CLX-IPI-T

  • Page 1 This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 2: Congratulations

    00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 3: Table Of Contents

    G. Control Module Operation ......51 A. Vent Termination Minimum Clearances ....22 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 4 D. Contact Information ......82 = Contains updated information. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 5: Limited Lifetime Warranty

    B. Limited Lifetime Warranty Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 6 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 7: Listing And Code Approvals

    CANADA 36,000 18,900 (2000-4500 FT) 45,000 22,000 (0-2000 FT) 8000CLX-IPI (NG) CANADA 40,500 19,800 (2000-4500 FT) 45,000 23,000 (0-2000 FT) 8000CLX-IPILP CANADA 40,500 20,700 (2000-4500 FT) Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 9: User Guide

    FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.J. MANTEL SECTION 5.D FAN KIT SECTION 2.C. HEARTH CLEAR SPACE SECTION 2.D. GRATE SECTION 3.C. Figure 2.1 General Operating Parts Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 10: Fan Kit

    For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 13: Maintenance And Service

    • Inspect draft shield to verify it is not damaged or missing. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    (Either cobrahead or SIT) • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 15: Refractory, Grate And Valve Assembly Removal

    NOTICE: Remove refractory before removing grate. If grate is removed fi rst, damage to refractory will occur. Figure 3.4 Grate Removal Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 16: Burner Identifi Cation/Verifi Cation

    Notch patterns are located on bottom side of burner. Figure 3.5 Base Refractory Removal NOTCH LOCATION 6000C 6000CL 6000CLX 6000CBV 8000C 8000CL 8000CLX 8000CBV Figure 3.7 Burner Identifi cation Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 17: Installer Guide

    IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH SECTION 12.C. MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 18: Design And Installation Considerations

    Manometer Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 19: Framing And Clearances

    Mantel Projections 1295 1067 1829 1438 55-7/8 61-1/2 19-3/4 See Section D. 8000 Mantel Projections 1419 1245 2007 1562 Figure 5.1 Appliance Locations - 6000 Models Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 20: Constructing The Appliance Chase

    * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 21: Mantel And Wall Projections

    Note: Measurement is taken from top of the opening, NOT the top of the fi replace. Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 22: Termination Locations

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 23: Heat & Glo • 6000Clx-Ipi-S, 6000Clx-Ipi-T, 8000Clx-S, 8000Clx-Ipi-T • 2166-900 Rev. F

    Figure 6.3 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 24: Vent Information And Diagrams

    DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 7.2 DVP Pipe Effective Length Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 25: Vent Diagrams

    90º elbow, to allow the vent pipe to clear the top standoffs. Figure 7.3 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 26 = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum = 20 ft. (6.1 m) Maximum = 1 ft. (305 mm) Minimum INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 27 16 ft * 4.9 m* 4 ft. 1.2 m 16 ft.* 4.9 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 7.5 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 28 2. Break the fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8). BREAK HERE Figure 7.8 Flue Restrictor Figure 7.6 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 29 20 ft. 6.1 m = 50 ft. (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 7.11 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 30 1.2 m 18 ft. 5.5 m 18 ft. 5.5 m = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 31 8000CLX 12 in. (305 mm) Figure 7.14 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.15 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 32 5.2 m 20 ft. 6.1 m = 40 ft. (12.2 m) Maximum = 3 ft. (914 mm) Maximum = 20 ft. (6.1 m) Maximum Figure 7.17 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 33 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m = 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED HORIZONTALLY Figure 7.19 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 34 = 40 ft. (12.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED Figure 7.21 HORIZONTALLY Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 35: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 36: Install The Ceiling Firestop

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 37: Install Attic Insulation Shield

    These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to Figure 8.6 Heat Zone Cover Plate maintain air space clearance. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 38: Appliance Preparation

    Figure 9.6 Remove the insulation from the outer vent pipe. For rear venting there is no insulation in the outer Figure 9.3 Remove the white gasket material covering the seal cap. vent pipe. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 39: Rear Vent

    (90º) and remove the insulation gasket. Figure 9.11 Discard the vent cap, remove and discard the insulation basket. Figure 9.9 Cut the metal retaining band and fold the sides out. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 40: Installing The Non-Combustible Board

    • Bend out nailing tabs on each side. Figure 9.15 Proper Positioning and Securing of an Appliance • Place the appliance into position. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 41: Installing Vent Pipe (Dvp And Slp Pipe)

    Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 42: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 10.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 43: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 44: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. WARNING! Risk of Fire! Clean out ALL materials from Figure 10.13 inside the support box and complete the vertical vent run and termination. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 45: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. Figure 10.17 Assembling the Storm Collar Around the Pipe Figure 10.17 Assembling the Storm Collar Around the Pipe Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 46: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.19. Figure 10.19 Wall Thimble Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 47: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 48: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 49: Electrical Information

    BOX 110VAC BATTERY PACK 6V DC (AA X 4) LED CONTROL FRONT EMBER LIGHTING (X 3) REAR ACCENT LIGHTING (X 2) Figure 12.1 IPI Wiring Diagram Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 50: Electrical Service And Repair

    (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 51: Control Module Operation

    REMOTE or ON. If the ignition command again fails, the module will emit an LED error code, prior to going back into LOCK-OUT mode. Contact your dealer for service if this occurs. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 52: Finishing

    2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Inches Millimeters ∞ Inches ∞ Millimeters Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 53: Doors

    They must be removed following fi nishing work. See Figure 13.7. Figure 13.4 Finishing Material 1 Inch Thick or Less Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 54 B = Top of door to bottom of fi replace. D = Bottom of Finishing Material to Bottom of Fireplace Figure 13.5 Finishing Material Thickness Greater Than One Inch Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 55 Remove glass frame assembly to access fi nishing strip screws. FINISHING STRIPS REMOVED Figure 13.7 Removing Finishing Strips. 31-7/8 IN. 3-3/4 IN. 35-5/16 IN. Figure 13.8. Clean Face Door Dimensions Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 56: Elevated Hearth Systems

    Note 1. Add dimensions to Wall Penetration (Figure 8.2) and Rough Opening Height (Figure 5.2). Note 2. Verify Marble Cut Lengths on site prior to cutting. Note 3. Dimensions assume use of a 3/4 in. Hearth Pad. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 57: Appliance Setup

    Using non-listed accessories could result in a safety hazard and will void the warranty. PILOT COVER BURNER ASSEMBLY BURNER SHIELD GUIDE SLEEVES Figure 14.1 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 58: Refractory Installation

    fi rebox lip. Let refractory foot rest on fi rebox af- ter panel’s notch has been mated with fi rebox lip. See Figure 3. Figure 5 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 59: Ember Placement

    fi t together and gaps should be minimized with correct installation. NO GAPS NO GAPS Figure 14.3 Embers Overlapping Burner Port Holes (LP only). Figure 7 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 60: Teco-Sil Placement

    • Fog the Teco-Sil to create a realistic coal bed appear- ance. NOT PAINTED NOT PAINTED Figure 14.5 Teco-Sil Not Painted TOO LIGHT TOO LIGHT Figure 14.6 Teco-Sil Too Light Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 61: Install The Log Assembly

    fi tted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 62 Log #7 to the left until the notch of Log #7 contacts the grate tine located 4th from the left as shown in Figure 11. 2166-935B LOG CONTACTS GRATE TINE LOG CONTACTS GRATE TINE Figure 11 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 63 After pin hole and pin have been fi tted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 64 Log #7 to the right until the notch of Log #7 contacts the grate tine located 4th from the left as shown in Figure 11. 2170-935B LOG CONTACTS GRATE TINE LOG CONTACTS GRATE TINE Figure 11 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 65: Fixed Glass Assembly

    • Install optional trim kits and/or surrounds using the instructions included with the accessory. • Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model). Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 66: Troubleshooting

    Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 67 fl ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 68: Reference Materials

    Inches Millimeters 1041 36-1/8 11-11/16 28-1/2 33-1/2 14-1/4 34-5/8 8-1/2 2-1/4 2-7/8 9-11/16 26-7/8 8-1/2 6 dia. 39-7/8 1013 40-7/8 1038 Figure 16.1 Appliance Dimensions-6000 Models Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 69 Location Inches Millimeters 1219 11-11/16 43-1/8 1096 34-3/8 35-1/2 17-3/4 36-5/8 2-3/8 8-1/2 2-7/8 9-15/16 28-7/8 8-1/2 41-7/8 1064 42-7/8 1089 Figure 16.1 Appliance Dimensions-8000 Models Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 70: Vent Components Diagrams

    (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 71 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.3 DVP vent components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 72 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 73 (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 74 SS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 16.6 DVP vent components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 75 SLP12A 2 - 12 51 - 305 SLP PIPE SLP-HVS SLP-FS SLP-WS Horizontal Pipe Ceiling Firestop Wall Shield Firestop Support Figure 16.7 SLP Series Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 76 Support Box-Black Termination Cap 26 in. 660 mm DVP-HSM-B DVP-2SL Extended Heat Shield Adapter SLP-DCF-BK SLP-WT-BK Ceiling Firestop Wall Thimble-Black Black Figure 16.8 SLP Series Vent Components Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 77: Service Parts

    6000CLX-IPI-S, -T, 8000CLX-IPI-S, -T C. Service Parts Beginning Manufacturing Date: Aug 2009 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 78 Refractory Kit Stratford SRV6CLXREF-STRT Back Refractory (-S) SRV2166-710 Left Refractory (-S) SRV2166-711 Right Refractory (-S) SRV2166-712 Top Refractory (-S) SRV2166-713 Additional service part numbers on following page. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 79 Refractory Kit Stratford SRV8CLXREF-STRT Back Refractory (-S) SRV2170-710 Left Refractory (-S) SRV2170-711 Right Refractory (-S) SRV2170-712 Top Refractory (-S) SRV2170-713 Additional service part numbers on following page. Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 80 Service Parts 6000CLX-IPI-S, -T, 8000CLX-IPI-S, -T Beginning Manufacturing Date: Aug 2009 Service Parts Diagram Ending Manufacturing Date: ________ IPI Valve Assembly Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 81: Service Parts

    8000CLX Conversion kits Conversion Kit NG NGKI-8CLX Conversion Kit LP LPKI-8CLX Pilot Orifi ce, NG 593-528 Pilot Orifi ce, LP 593-527 Regulator, NG NGK-DXV-50 Regulator, LP LPK-DXV-50 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...
  • Page 82: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2009 Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. F • 11/09...

Table of Contents