USER MANUAL
A6000
AC POWER SOURCE
VERion:UI?
Function
Example
Parameter returns: S00E00
INSTrument:NSELect 1 | 2
Function
Example
Parameter : 1 | 2
Parameter returns: 1 | 2
SYSTem:ERRor?
Function
Example
Parameter returns: Return NORMAL for no errors. Refer strings in paragraph 3.7 for
SYSTem:ERRor:(1, 2)?
Function
Example
Parameter returns: Return NORMAL for no errors. Refer strings in paragraph 3.7 for
6.11.5 Summary of Commands
Common commands
*ESE <n>
*ESE?
*ESR?
*IDN?
*RCL <n>
*SAV <n>
*SRE <n>
*SRE?
*STB?
*CLS
95
│ www.deltaww.com
: Query firmware version for UI.
: VERion:UI?
: set specific output phase for responcing queries:
: INSTrument:NSELect?
INSTrument:NSELect 2
: Query error status, must be used together with INSTrument:NSELect
command.
: SYSTem:ERRor?
specific error.
: Query error status for specific output phase
: SYSTem:ERRor:1?
specific error.
Set flag mask of standard event status register
Query flag mask for standard event status register
Query value stored in standard event register, 1 represents event occurs.
Query series number for AC source
Recall previously stored system setting
Save system setting into a specific group in memory.
Set flag mask for service events register
Query flag mask for service events register
Query value stored in service event register, 1 represents event occurs.
Leave REMOTE mode, back to front panel control
Query which phase is set for query.
Query Φ2status
Query Φ1 status