3.20 Inhibit Output by Remote Control Signal (Remote Inhibit)

Remote Inhibit is a "Active HIGH" TTL signal, high level is 5V, low level is 0V. Its
signals send to 9 pin TTL signal connector (D-SUB) at back panel of the AC source. Please
refer appendix A for pin assignment.
After Remote Inhibit initialized, output control priorities for AC source are as below:
 When both front panel and remote control are idle, output of DME-A602ABS SERIES is
according to external TTL ON/OFF signal.
 When user press "OUT" from front panel or by remote control, TTL signal has no effect
on the operation.
There are four Remote inhibit output status: OFF, LIVE, TRIG, EXCITE.
 OFF: Turn off remote inhibit function.
 LIVE: two conditions
 TTL signal changes from HIGH→LOW, and stayes low longer than 1ms,
DME-A602ABS SERIES turn off output.
 TTL signal changes from LOW→HIGH, and stayes high longer than 1ms,
DME-A602ABS SERIES resume output.