Voltage Level Setting - Delta A6000 User Manual

Table of Contents

Advertisement

USER MANUAL
A6000
AC POWER SOURCE
4. Change to 1.5s by numerical key or knob, then press

3.10 Voltage Level Setting

DME-A602ABS SERIES provide two output voltage levels used for low voltage and
high voltage applications. At 300V level, AC source can provide 32A in total; At 150V level
64.0A in total can be provided, maximum output power is 6000W.
When switched from 300V to 150V level, AC source will check all voltage settings, and
change the setting to 150V if any voltage setting checked is higher than 150V.
When switched from 150V to 300V level, AC source will check all I Limit settings, and
change the setting to 32.0A if any current setting checked is higher than 32.0A.
Following processes demonstrate how to change output voltage level (300V→150V):
1. Press
31
│ www.deltaww.com
or
to move cursor to Voltage Level
key to confirm the setting