Command Usage
If you do not enter an snmp-server enable traps command, no
notifications controlled by this command are sent. In order to
configure this device to send SNMP notifications, you must enter at
least one snmp-server enable traps command.
If you enter the command with no keywords, all notification types are
enabled. If you enter the command with a keyword, only the
notification type related to that keyword is enabled.
The snmp-server enable traps command is used in conjunction
with the snmp-server host command. Use the snmp-server host
command to specify which host or hosts receive SNMP notifications.
In order to send notifications, you must configure at least one
snmp-server host command.
The notification types used in this command all have an associated
MIB object that allows them to be globally enabled or disabled. Not
all of the notification types have notification Enable MIB objects, so
some of these cannot be controlled using the snmp-server enable
traps command.
Example
Console(config)#snmp-server enable traps link-up-down
Console(config)#
Related Commands
snmp-server host
show snmp
Use this command to check the status of SNMP communications.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
SNMP C
OMMANDS