Calibrate Sensor

<ESC>CA
Example:
<ESC>CA
Placement:
This command should be sent after the sensor type has
been selected with the <ESC>CI command. It should
not be included with print job commands.
Default:
There is no default for this command.
To adjust the label sensor for unique media and ribbon combinations.
<ESC>A
<ESC>CI2
<ESC>CA
<ESC>Z
There is no printer output for this command. It will cause the printer to
feed a label while the characteristics of the label backing or eye-mark
are measured.
1. The sensor is calibrated for the currently selected sensor type
(Eye-Mark or Transmissive).
2. If the Sensor is disabled with a <ESC>CI0 command, no calibration
is performed.
3. The sensor must be recalibrated whenever the sensor type is
changed.
4. When calibrating the sensor for the CX200TT Thermal Transfer unit
operating in the thermal transfer mode, the ribbon must be
installed in the printer.