Calibrate Sensor - SATO CX Series Programming Manual

Sato printer programming manual cx series
Hide thumbs Also See for CX Series:
Table of Contents

Advertisement

Command Structure
<ESC>CA
Example:
Placement:
Default:
Command Function
To adjust the label sensor for unique media and ribbon com-
binations.
Input to Printer
<ESC>A
<ESC>CI2
<ESC>CA
<ESC>Z
Printer Output
There is no printer output for this command. It will cause the
printer to feed a label while the characteristics of the label
backing or eye-mark are measured.
Special Notes
1. The sensor is calibrated for the currently selected sensor
2. If the Sensor is disabled with a <ESC>CI0 command, no
3. The sensor must be re-calibrated whenever the sensor
4. When calibrating the sensor for the CX Series TT Ther-

Calibrate Sensor

Calibrate Sensor
Calibrate Sensor
Calibrate Sensor
<ESC>CA
This command should be sent after the sensor
type has been selected with the <ESC>CI
command. It should not be included with print
job commands.
There is no default for this command.
type (Eye-Mark or Transmissive).
calibration is performed.
type is changed.
mal Transfer unit operating in the thermal transfer
mode, the ribbon must be installed in the printer.
SATO CX Series Printer
95