Technical Data
This cooker is category II
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB
Gas
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Minimum space above hotplate
Connections
Gas:
Rp 1/2 at rear right-hand side
Ratings
Hotplate
Right hand Wok burner
Large Burners
Medium Burners
Small Burner
Gas burner inputs based on Gross Calorifi c Value
2H3+
20mbar
29mbar
37mbar
Overall height
minimum 896mm
Overall width
1100mm See 'Positioning of Cooker'
Overall depth
648mm
Space for fixing
See 'Positioning of Cooker'
650mm
Natural Gas
3.65kW
3.0kW
1.7kW
1.0kW
Electric
220 - 240V 50Hz
maximum 925mm
Electric
220 - 240V 50Hz
L.P. Gas
Injector
internal 80
3.5kW (255g/h)
external 129
134
3.0kW (218g/h)
109
1.7kW (124g/h)
75
1.0kW (73g/h)
34
Injector
internal 54
external 77
87
68
51