Technical Data; Natural Gas - Rangemaster Kitchener 110 Dual Fuel Users Manual & Installation

Installation & service instructions
Hide thumbs Also See for Kitchener 110 Dual Fuel:
Table of Contents

Advertisement

Technical Data

This cooker is category II
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB
Gas

Natural Gas

Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Minimum space above hotplate
Connections
Gas:
Rp 1/2 at rear right-hand side
Ratings
Hotplate
Right hand Wok burner
Large Burners
Medium Burners
Small Burner
Gas burner inputs based on Gross Calorifi c Value
2H3+
20mbar
29mbar
37mbar
Overall height
minimum 896mm
Overall width
1100mm See 'Positioning of Cooker'
Overall depth
648mm
Space for fixing
See 'Positioning of Cooker'
650mm
Natural Gas
3.65kW
3.0kW
1.7kW
1.0kW
Electric
220 - 240V 50Hz
maximum 925mm
Electric
220 - 240V 50Hz
L.P. Gas
Injector
internal 80
3.5kW (255g/h)
external 129
134
3.0kW (218g/h)
109
1.7kW (124g/h)
75
1.0kW (73g/h)
34
Injector
internal 54
external 77
87
68
51

Hide quick links: