Connecting to Console Port for Local Management
2. Plug the RJ45 connector at the other end of the cable ➀ into the RJ45-to-DB25 male adapter ➂.
3. Connect the RJ45-to-DB25 adapter ➂ to the communications port of the modem ➃.
4. At the remote site, ensure that the PC ➄ is connected to the modem ➅.
5. Turn on the modem and configure your VT emulation package with the following parameters:
When these parameters are set, the startup screen will display. Proceed to
the installation.
Figure 3-23 Connecting to a Modem
Ä
straight-through
UTP
connectors
RJ45 console port
3-32
Hardware Installation
Parameter
Mode
Transmit
Bits Parity
Stop Bit
Å
Ã
cable with RJ45
Setting
7 Bit Control
Transmit=9600
8 Bits, No Parity
1 Stop Bit
Â
RJ45-to-DB25 modem adapter
RJ45 modem port
Section 3.10
1G582-09
PWR
CPU
RESET
COM
Á
À
PC
Modem
to complete