Installation Guide
Figure 4: Component Layout
1.3 Environmental Specifications
Table 2: Environmental Specification
Temperature Gradient
Temperature De-rating
Relative Humidity
Relative Humidity Gradient
1.4 Electrical Specifications
Table 3: Electrical Specifications
Max Power Consumption
Typical Power Consumption
PSU Connector Type
2.
Max and typical power consumption values represent the output power to the system. Input power will vary depending on
the PSU efficiency and load sharing between PSUs.
Specification
Non-Operational
Temperature
30°C per hour max
1°C per 300m above 3000m
8-90% Non-Condensing
30% per hour maximum
Altitude
-300m to 12,000m /
-984 ft. to 39,370 ft
Specification
2
Input Voltage
-40°C to 70°C
~1000W
200-240 VAC
1.3 Environmental Specifications
Operational
5°C to 35°C
20°C per hour max
1°C per 300m above 900m
8-90% Non-Condensing
30% per hour maximum
-300m to 3048m /
-984 ft. to 10,000 ft.
Value
1250W
C14
1. Overview
4