Install the outer rails into the rack. Pay special attention to which side is being installed. The
Step 4 :
embossed R is for the right side and L is for the left side. Right and Left refer to when you are
facing the front of the rack.
a. Move to the rear of the rack.
b. Orient the rail so that the word "REAR" that is embossed into the metal of the rail is at the
rear end of the rack, and the release latch is facing the inside of the rack posts as shown in
the following image.
Figure 19: Rear Rail Latch Release Latch
c. Align the rail on the rack posts at the U-height desired for installation. The bottom of the rail
will be the lower most U of the total 4U height.
d. Pull the rail toward the rack post until the toolless latching mechanism engages the rack. The
latching mechanism may need to be pulled open to get around the rack post.
e. Move to the front of the rack.
Ensure that all of the vertical rails are set to the same depth using a tape
Note:
measure.