Burner 2
Valve
Step
Motor
Gas Valve
Optional
Fixed
Outlet
BGE18PE
• Rating (Variable): 24,000/30,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
BGE18NE
• Rating (Variable): 21,000/30,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
900703-00C
WIRING DIAGRAM
Main Burner
Thermocouple Ground -
Connector to Chassis
Ground or Valve Body
Thermocouple - To "S"
Terminal on Main Module
Dry -
Contact
Switches
Battery
Pack
" – "
Black
(Primary or
Backup)
" + "
Red
Valve
Safety Operator
Regulator
Inlet
Figure 51 - Wiring Diagram
SPECIFICATIONS
BGE2436PE
• Rating (Variable): 30,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
BGE2436NE
• Rating (Variable): 26,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
SuperiorFireplaces.us.com
Pilot
Learn (Black)
Optional: Hi/Lo (Blue)
On/Off (Brown)
SWITCHES
From Pilot
Thermocouple
To Pilot
Igniter
Remote
Control
ON THERMO OFF
Cont.
ROOM
Pilot
°
°
SET
S M T W T F S
P1
PROGRAM
P2
:
AM
P1
P2
PM
A
MODE/SET
POWER