Cleaning And Maintenance - Superior Fireplaces BGE18NE Installation And Operation Instruction Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

BURNER FLAME PATTERN
Figure 47, shows correct burner fl ame pat-
tern. Figure 48, shows incorrect burner fl ame
pattern.
WARNING: If incorrect burn-
er flame occurs, your heater
could produce increased levels
of carbon monoxide.
NOTICE: Do not mistake orange
fl ames with yellow tipping. Dirt
or other fi ne particles are burned
by heater, causing brief patches
of orange fl ame.
If burner fl ame pattern is incorrect, as shown
in Figure 48.
• turn heater off (see To Turn Off Gas to Ap-
pliance, Page 22).
• see Troubleshooting, Page 32

CLEANING AND MAINTENANCE

WARNING: Turn off heater
and let cool before cleaning.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result
in sooting and property damage.
900703-00C
INSPECTING BURNERS
Continued
Middle
burner fl ame
should be
blue with
the ramp/
log glowing
orange/red
Figure 47 - Correct Burner Flame Pattern
Yellow
tipping
on ember
burner
trol areas, burners and circulating
air passageways of heater clean.
Inspect these areas of heater
before each use. Have heater
inspected yearly by a qualifi ed
service person. Heater may need
more frequent cleaning due to
excessive lint from carpeting, pet
hair, bedding material, etc.
SuperiorFireplaces.us.com
Bright yellow
rear burner
fl ame; fl ame
will be blue
next to burner
Dark orange rear
burner fl ame
Figure 48 - Incorrect Burner Flame
Pattern
CAUTION: You must keep con-
Small blue
fl ame on
ember
burner with
no yellow
tipping
Yellow or
dark orange
middle
burner fl ame
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents