Replacement Parts; Service Hints; Technical Service; Specifications - Superior Fireplaces TF18PR Installation And Operation Instructions Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call INNOVATIVE HEARTH PROD-
UCTS at 1-800-655-2008.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TF18NR
• Rating (Variable): 21,000/30,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
TF2430NR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
Thermopile
126816-01A

REPLACEMENT PARTS

SPECIFICATIONS

*For purpose of input adjustment

WIRING DIAGRAM

To
www.SuperiorFireplaces.US.com
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to
the factory.

TECHNICAL SERVICE

You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact INNOVATIVE HEARTH PRODUCTS
at 1-800-655-2008. When calling please
have your model and serial numbers of your
heater ready.
You can also visit our web site at
www.IHP.US.com.
TF18PR
• Rating (Variable): 24,000/30,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
TF2430PR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
To OFF Terminal
on Switch
To AUTO Terminal
on Switch
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tf18nrTf2430nrTf2430rpTf2430pr

Table of Contents