Inspecting Burners - Superior Fireplaces BGE18NE Installation And Operation Instruction Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

SWITCHING ON
To turn the system on, press the Burner ON/
OFF switch to the ON position (see fi gure
on Page 27). Once the start up process is
complete, the main burner and pilot will be lit.
REGULATING THE FLAME LEVEL.
1. To decrease the fl ame level to low, press
the Hi-Low switch to the ON position.
2. To increase to high fl ame level, press the
Hi-Low switch to the OFF position.
NOTE: If the appliance is set to the low fl ame
level and turned off, it will light on high fl ame
level and then cycle to low fl ame level on the
next fl ame sequence.
Check pilot fl ame pattern and burner fl ame
patterns often.
PILOT FLAME PATTERN
Figure 45, Page 29 shows a correct pilot
fl ame pattern. Figure 46, Page 29 shows an
incorrect pilot fl ame pattern. The incorrect pilot
fl ame is not touching the thermocouple. This
will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down.
If pilot fl ame pattern is incorrect, as shown in
Figure 46, Page 29.
• turn heater off (see To Turn Off Gas to Ap-
pliance, Page 22
• see Troubleshooting, Page 35
NOTE: The pilot fl ame on natural gas units will
have a slight curve, but fl ame should be blue
and have no yellow or orange color.
28
OPERATION
Continued
SWITCHING OFF
To switch off the fi re, press the Burner ON/OFF
Switch to the OFF position.
heater to use different fuel type.
Only use heater with fuel type
specifi ed.
Thermocouple

INSPECTING BURNERS

(Your pilot may vary from pilots shown)
Figure 46 - Incorrect Pilot Flame Pattern
(Your pilot may vary from pilots shown)
SuperiorFireplaces.us.com
WARNING: Do not convert
Igniter Electrode
Figure 44 - Pilot (Natural)
Thermocouple
Figure 45 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot Burner
Pilot Burner
900703-00C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents