3 System-defined Variables Related to the Built-in EtherNet/IP Port
Variable name
Meaning
_EIP_IdentityErr
Identity Error
_EIP1_IdentityErr
CIP Communica-
tions1 Identity Error
_EIP2_IdentityErr
CIP Communica-
tions2 Identity Error
_EIP_TDLinkCfgErr
Tag Data Link Setting
Error
_EIP1_TDLinkCfgErr
CIP Communica-
tions1 Tag Data Link
Setting Error
_EIP2_TDLinkCfgErr
CIP Communica-
tions2 Tag Data Link
Setting Error
3-12
Function
NX-series CPU Units: Indicates that the
identity information for CIP communica-
tions 1 (which you cannot overwrite) is
incorrect. Or, a read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
NJ-series CPU Units: Indicates that the
identity information (which you cannot
overwrite) is incorrect. Or, a read opera-
tion failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Indicates that the identity information for
CIP communications 1 (which you cannot
overwrite) is incorrect. Or, a read opera-
tion failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Note You can use this system-defined vari-
able only for NX-series CPU Units.
Indicates that the identity information for
CIP communications 2 (which you cannot
overwrite) is incorrect. Or, a read opera-
tion failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Note You can use this system-defined vari-
able only for the NX701 CPU Units
and NX102 CPU Units.
NX-series CPU Units: Indicates that the
tag data link settings for CIP communica-
tions 1 are incorrect. Or, a read operation
failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
NJ-series CPU Units: Indicates that the
tag data link settings are incorrect. Or, a
read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Indicates that the tag data link settings for
CIP communications 1 are incorrect. Or, a
read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Note You can use this system-defined vari-
able only for NX-series CPU Units.
Indicates that the tag data link settings for
CIP communications 2 are incorrect. Or, a
read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Note You can use this system-defined vari-
able only for the NX701 CPU Units
and NX102 CPU Units.
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page 3-43
page 3-43
page 3-44
page 3-44
page 3-44
page 3-44