Variable name
Meaning
_EIP2_CipErr
CIP Communica-
tions2 Error
_EIP_TcpAppErr
TCP Application
Communications
Error
_EIP_MacAdrErr
MAC Address Error
_EIP1_MacAdrErr
Port1 MAC Address
Error
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Function
This is the error status variable for CIP
communications 2.
It represents the collective status of the
following error flags.
• _EIP2_IdentityErr (CIP Communications2
Identity Error)
• _EIP2_TDLinkCfgErr (CIP Communica-
tions2 Tag Data Link Setting Error)
• _EIP2_TDLinkOpnErr (CIP Communica-
tions2 Tag Data Link Connection Failed)
• _EIP2_TDLinkErr (CIP Communications2
Tag Data Link Communications Error)
• _EIP2_TagAdrErr (CIP Communications2
Tag Name Resolution Error)
• _EIP2_MultiSwONErr (CIP Communica-
tions2 Multiple Switches ON Error)
Note If a Tag Name Resolution Error
occurs, it is recorded in the event
log and this variable changes to
TRUE. Refer to information on the
meanings of the error status bits at
the end of this appendix for details.
Note You can use this system-defined vari-
able only for the NX701 CPU Units
and NX102 CPU Units.
This is the error status variable for TCP appli-
cation communications.
It represents the collective status of the
following error flags.
• _EIP_TcpAppCfgErr (TCP Application Set-
ting Error)
• _EIP_NTPSrvErr (NTP Server Connection
Error)
Note Refer to information on the mean-
ings of the error status bits at the
end of this appendix for details.
NX-series CPU Units: Indicates that an
error occurred when the MAC address
was read on the communications port 1 at
startup.
TRUE: Error
FALSE: Normal
NJ-series CPU Units: Indicates that an
error occurred when the MAC address
was read at startup.
TRUE: Error
FALSE: Normal
Indicates that an error occurred when the
MAC address was read on the communi-
cations port 1 at startup.
TRUE: Error
FALSE: Normal
Note You can use this system-defined vari-
able only for NX-series CPU Units.
Range of
Data type
values
WORD
16#0000 to
16#00F0
WORD
16#0000 to
16#00F0
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page 3-37
3
page 3-37
page 3-37
page 3-38
3-7