 Functional Classification: EtherNet/IP Communications Switches
You can start and stop tag data links.
Variable name
Meaning
_EIP_TDLinkStart-
Tag Data Link Com-
Cmd
munications Start
Switch
_EIP1_TDLinkStart-
CIP Communica-
Cmd
tions1 Tag Data Link
Communications Start
Switch
_EIP2_TDLinkStart-
CIP Communica-
Cmd
tions2 Tag Data Link
Communications Start
Switch
_EIP_TDLinkStop-
Tag Data Link Com-
Cmd
munications Stop
Switch
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Function
NX-series CPU Units: Change this vari-
able to TRUE to start tag data links for CIP
communications 1.
It automatically changes back to FALSE
after tag data link operation starts.
NJ-series CPU Units: Change this vari-
able to TRUE to start tag data links.
It automatically changes back to FALSE
after tag data link operation starts.
Note Do not force this switch to change
to FALSE from the user program or
from the Sysmac Studio. It changes
to FALSE automatically.
Change this variable to TRUE to start tag
data links for CIP communications 1.
It automatically changes back to FALSE
after tag data link operation starts.
Note Do not force this switch to change
to FALSE from the user program or
from the Sysmac Studio. It changes
to FALSE automatically.
Note You can use this system-defined vari-
able only for NX-series CPU Units.
Change this variable to TRUE to start tag
data links for CIP communications 2.
It automatically changes back to FALSE
after tag data link operation starts.
Note Do not force this switch to change
to FALSE from the user program or
from the Sysmac Studio. It changes
to FALSE automatically.
Note You can use this system-defined vari-
able only for the NX701 CPU Units
and NX102 CPU Units.
NX-series CPU Units: Change this vari-
able to TRUE to stop tag data links for CIP
communications 1.
It automatically changes back to FALSE
after tag data link operation stops.
NJ-series CPU Units: Change this vari-
able to TRUE to stop tag data links.
It automatically changes back to FALSE
after tag data link operation stops.
Note Do not force this switch to change
to FALSE from the user program or
from the Sysmac Studio. It changes
to FALSE automatically.
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page 3-58
3
page 3-58
page 3-58