Field Service Ver. 1.0 Aug. 2007
11.3 SERVICE'S CHOICE
11.3.1
TX SPEED
Function
• Transmit start speed setting. Choose the mode from among the following.
Use
• The default setting is V.34 33600.
"V.34": "33600", 31200, 28800, 26400, 24000, 21600, 19200, 16800
Setting/
V.17: 14400, 12000, 9600, 7200
procedure
V.29: 9600, 7200
V.27: 4800, 2400
11.3.2
RX SPEED
Function
• Reception start speed setting. Choose the mode from among the following.
Use
• The default setting is V.34 33600.
"V.34": "33600", 31200, 28800, 26400, 24000, 21600, 19200, 16800
Setting/
V.17: 14400, 12000, 9600, 7200
procedure
V.29: 9600, 7200
V.27: 4800, 2400
11.3.3
TX LEVEL
Function
• PSK/FSK signal output level.
Use
• The default setting is -9 dBm.
Setting/
procedure
-17 to -10 dBm
11.3.4
RX LEVEL
Function
• Reception sensitivity level.
Use
• The default setting is -43 dBm.
Setting/
procedure
-49 to -44 dBm
11.3.5
DTMF LEVEL
Function
• Dual tone output level.
Use
• The default setting is -9 dBm.
Setting/
procedure
-17 to -10 dBm
"-9 dBm"
-8 to -2 dBm
"-43 dBm"
-42 to -36 dBm
"-9 dBm"
-8 to -2 dBm
11. SERVICE MODE