Field Service Ver. 1.0 Aug. 2007
B. Removal procedure
1. Open the top cover.
See P.31
2. Remove the drum cartridge.
See P.16
4. Using a cleaning pad dampened with
alcohol, wipe the pick-up roller [1]
[1]
clean of dirt.
4139F2C516DA
NOTE
• Position the removed drum car-
tridge as shown in the illustration at
the left.
• Be sure to keep the drum cartridge
horizontal and place it where it will
not become dirty.
• Do not leave the drum cartridge
removed for more than 15 minutes,
and do not place the removed drum
cartridge in a location where it will
be exposed to direct light (such as
4139fs2538c0
sunlight).