Site Selection Conditions

KSU Installation Site
The following conditions should be met at the site selected for the KSU.
1.
2.
3.
44
The KSUs should be wall mounted to protect against accident or flooding.
The KSU should not be located directly beneath pipes, due to the possibility of
leaks or condensation causing damage to the equipment.
The area where the KSU is to be located must be free of corrosive and
inflammable gases, excessive chemical or industrial dusts and other materials that
could cause a hazard to personal or to the proper functioning of the equipment.
Operating ambient temperature and humidity must be within the limits specified in
– Environmental Conditions in Chapter 1.
Section 8
The operation of the system is virtually noiseless and allows a wide selection of
installation sites. Care should be taken to ensure the KSUs do not present a
hazard to office traffic. For purposes of economy, a central location to minimise
cabling is often used.
The basic KSU weighs approximately 4 Kg. Select a strong wall for mounting
purposes.
Place the KSU according tot he following spacing specifications
Space distance between the KSU and the ceiling:
Space distance on both sides of the KSU:
Space distance on front of KSU:
Avoid connection of the KSU to an AC receptacle used in common with any other
device (computer, facsimile machine, copier, etc.)
Ensure that any AC Outlet to be connected is properly grounded.
Avoid connection of KSU near radio receivers or electrical noise generators (e.g.
welding equipment, machinery).
The socket outlet shall be installed near the equipment and shall be easily
accessible.
Plug the system into the mains supply (240V AC) before terminating a
telecommunications network conductor to the system.
Danger of explosion if batteries are incorrectly replaced. Replace only with the
same or equivalent type recommended by the manufacturer. Dispose of used
batteries according to the manufacturers instructions
50 cm or more
30 cm or more
50 cm or more
CAUTION
Installation Manual, Chapter 2 – KSU Installation