Advertisement

Connecting the unit

6.2.1 Connecting the electrical connection line

DANGER
28
Insulation monitoring
In the case of an unearthed network (IT network), the unit can be
incorporated into the insulation monitoring.
Fault current device
Image: RCD switch type A circuit symbol
The unit can be connected to a fault current device.
If a residual-current circuit breaker is used, the residual-current circuit
breaker installed must be type A (RCD type A ) to ensure that AC fault
currents and pulsating DC fault currents are detected.
If the unit is connected to electrical supply mains without a neutral
conductor, a type B fault current circuit breaker (RCD type B), which is
sensitive to all types of current, must be installed.
The unit generates a small fault current through use of special
electronic components. To ensure that the residual current device does
not trip during normal operation, each unit should have its own residual
current device.
Potential equalization
Image: Potential equalization symbol
The unit can be included in a potential equalization system by means of
appropriately sized wiring.
Risk of operator injury and property damage from electric shock
• Before connecting, make sure that the connection point at the installation
site is dead.
• Make sure that the connection line is undamaged.
Installation instructions