Regulatory information

FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Complies with Part 68 FCC Rules.
ACTA (FCC) ID: GCQUSA-33408-AL-E
IC: 1175A-NXV2
2002/96/EC (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.

ANSI/SIA CP-01 requirements

CP-01 feature descriptions and specifications are listed in
CP-01 standards.
Note:
Where a conflict exists, UL requirements take precedence over ANSI/SIA requirements.
Minimum system requirements:
One control panel
Two keypads
Do not enable remote arming in SIA classified installations.
Off premise transmission must be in the SIA format.
Do not exceed 1 minute for the abort window and entry delay.
Note:
A call-waiting cancel on a noncall-waiting line prevents successful connection to the central station
Table 7. CP-01 feature descriptions and specifications
CP-01 feature description
Exit time
Progress annunciation /
disable for silent exit <1>
Exit time restart (reexit)
Auto stay arm on unvacated
premises
Exit time and progress
annunciation/disable for
remote arm
Entry delays <2>
Abort window - for
nonfire zones
Abort window time - for
nonfire zones <2>
NX-6V2 Control Panel Installation Instructions
Feature description as
Progra
shown in manual
m
location
Exit 1 delay
24
Exit 2 delay
24
Silent keypad option
93
This feature is not programmable in the panel.
Auto bypass
23
This feature is not programmable in the panel. Exit time and
progress are always enabled.
Exit 1 delay
24
Exit 2 delay
24
Dialer delay
40
Dialer delay
40

Contact information

For contact information, see www.utcfireandsecurity.com or
www.interlogix.com.
For technical support, Toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada. Outside
the tool-free area: Contact your dealer.
Copyright © 2011 UTC Fire & Security. All rights reserved.
Table
7. The following are requirements for compliance with ANSI/SIA
Seg/op
Default
t
2
60
4
60
2
All
annunciators
enabled
1/3
Enabled
1
30
3
30
8
30
8
30
CP-01 required setting
45 to 240 seconds
45 to 240 seconds
Allowed (individual keypads may be disabled)
Enabled
Enabled
Enabled (disabled for remote arming)
30 to 240 seconds
30 to 240 seconds
Enabled (may be disabled by zone/zone type,
but no cancel reports will be sent)
15 to 45 seconds