7.
Remove the two (2) light blockers. Each will have two
(2) screws securing it (4 screws in total).
8.
Remove the three (3) screws securing the bottom glass
retainer assembly.
MAINTENANCE AND SERVICE
9.
2× Green wires to
10.
11.
Lift the bottom glass retainer assembly out a little.
Disconnect the wires on the left side of the wiring
harness and set it to the side.
Yellow and
Purple wires to
BLACK Button
GREEN Button
Lift the bottom trim out.
Optional - Remove the top glass retainer mount, which
is secured with five (5) screws. (glass can be removed
with retainer in place - care to be taken)
LED Connector